Two-way wireless system ABAX
ACU-100
6
2.2 F
UNCTIONS OF
DIP-
SWITCHES
DIP-switch number
Controller function
1
2
3
4
5
6
7
8
Wireless device module for all control panels
I
1
I
2
I
3
x P 0 0 0
Expander for CA-10 with 1 keypad (6 zones)
A B C D P 1 0 0
Expander for CA-10 with 2 keypads (4 zones)
A B C D P 0 1 0
Expander for CA-10 with 3 keypads (2 zones)
A B C D P 1 1 0
Addressable zone expander for CA-64
A
1
A
2
A
3
A
4
A
5
P 0 1
Wireless device expander for INTEGRA or VERSA control
panels
A
1
A
2
A
3
A
4
A
5
x 1 1
Table 1. The way of using DIP-switches for controller configuration.
0
– DIP-switch in OFF position
1
– DIP-switch in ON position
P
– selection of controller programming mode:
−
DIP-switch in OFF position – through RS-232 port (D
LOAD
10 program)
−
DIP-switch in ON position – by means of LCD keypad
I
1
,
I
2
,
I
3
– DIP-switches for setting the number of ACX-100 modules connected to the
computer. To determine this number, tot up the values set on individual DIP-switches as
per Table 2.
DIP-switch number
1
2
3
Numerical value
(for switch in ON position)
1 2 4
Table 2.
The controller accepts up to 5 input/output expansion modules, hence if a higher value
is set on the DIP-switches, it will be also recognized as 5.
A
,
B
,
C
,
D
– DIP-switches for setting the controller address in the same way as with the
CA-10 zone expanders. When in the ON position, the switch value is 1.
A
1
,
A
2
,
A
3
,
A
4
,
A
5
– DIP-switches for setting the controller address. In order to determine the
controller address, add up the values set on individual DIP-switches as per Table 3.
DIP-switch number
1
2
3
4
5
Numerical value
(for switch in ON position)
1 2 4 8 16
Table 3.
x
– unused DIP-switch
2.3 C
ONTROL INPUTS
If the controller is working as an expander with the INTEGRA or VERSA control
panel, you are not required to know how the control inputs operate, because
they need not be connected to the control panel (all information will be sent to
the control panel via communication bus).