ACU-100 SATEL
33
Communication with the control panel in this configuration is effected by means of controller
outputs and inputs. The controller outputs to which the wireless devices are assigned should
be connected to the control panel zones. Control of the detectors (changeover to
active/passive state), sirens (triggering alarm signal), 230 V AC controller (closing/opening
the electric circuit) etc. is performed through the control inputs of the ACU-100 controller.
Suitably programmed outputs of the alarm control panel should be connected to the control
inputs.
Shown in the example, Fig. 14, is the CA-6 alarm control panel of SATEL make, however it
can be any other panel as well. The controller outputs OUT1 to OUT5 are connected,
respectively, to the control panel zones Z1 to Z5 (preprogrammed as type NO). The TPR
output, which informs of tampers of wireless devices and controller (TMP terminals
connected to COM and ITMP terminals), is connected to the Z6 panel zone, preprogrammed
as NO type, reaction type 24H
A
UDIBLE
. The OUT4 panel low-current output has been
programmed as type 35: P
OWER SUPPLY ON ARMED MODE
and connected to the AR1 controller
control input. This input toggles the wireless detectors between the passive and active state.
The OUT5 panel low-current output has been programmed as type B
URGLARY ALARM
SIGNALING
and connected to the AR2 controller control input. This input triggers the wireless
siren.
11. P
ROGRAMMING AND DIAGNOSTICS
The way of programming and the access to diagnostic functions depend on the working
configuration of the controller:
•
interacting with INTEGRA or VERSA control panels
−
keypad of alarm system in service mode;
−
computer with D
LOAD
X program connected to INTEGRA control panel;
−
computer with D
LOAD
10 program connected to the RS-232 port of the controller for the
duration of diagnostic test.
•
interacting with other control panels
−
LCD keypad to be connected to the controller for the time of programming;
−
computer with D
LOAD
10 program connected to controller RS-232 port for the time of
programming.
11.1 LCD
KEYPAD OF
INTEGRA
SECURITY SYSTEM
1. Enter the service code, confirm with the [*] key and press the key 9 to get access to the
service mode.
2. Proceed to the function of programming the controller settings a (
Æ
S
TRUCTURE
Æ
H
ARDWARE
Æ
E
XPANDERS
Æ
S
ETTINGS
Æ
controller name
).
3. Program the controller as required.
4. Quit the service mode.