Two-way wireless system ABAX
ACU-100
22
AMD-102
– wireless magnetic contact with input for roller shutter detector. For the magnetic
contact, you must specify which of the two reed switches on the electronics board is to
be active. For the roller shutter input, you must program the following:
– number of pulses, the registration of which will cause violation of the input;
– pulse validity (the time counted from the pulse occurrence, during which next pulses
must occur for the input to become violated).
Note:
The counter of pulses is reset after the pulse validity time expires and after
switching the detector over from passive into active mode.
AGD-100
– wireless glass break detector. Sensitivity of the high-frequency channel is to be
programmed.
AVD-100
– wireless vibration detector and magnetic contact. Determine for the magnetic
contact which of the two reed switches on the electronics board is to be active. Program
the following for the vibration detector:
– sensitivity (a single vibration meeting the sensitivity criterion will cause violation of
the detector);
– number of pulses. Registering the predefined number of vibrations within 30
seconds will cause violation of the detector. All vibrations count (they do not have to
meet the sensitivity criterion). For the value 0, the pulses are not counted.
Note:
Parameters are being independently analyzed. As a result, the detector can
signal violation after registering a strong single vibration, caused by a powerful
impact, as well as after a few slight vibrations, caused by a series of weak
strikes.
ASD-100
– wireless smoke and heat detector. The following is to be programmed:
– operating
mode
of
the heat detector;
– operating mode of the buzzer;
– duration of alarm signaling by buzzer/LED.
ARD-100
– wireless reorientation detector. Sensitivity is to be programmed.
ATD-100
– wireless temperature detector. For each position taken by the detector, preset the
following temperature threshold parameters:
– threshold type: high (the detector will report violation, when the temperature rises
above the defined value) or low (the detector will report violation, when the
temperature drops below the defined value);
– temperature;
– tolerance.
7. S
IRENS IN
ABAX
SYSTEM
The sirens sent information on tampers and (storage) battery/power supply status to the
ACU-100 controller. The information on tampers is sent immediately, while all the other
information - at the response time (see: R
ESPONSE PERIOD
).
Note:
Signaling of the tamper alarm is blocked:
–
on entering the test mode,
–
on entering the service mode, if working in conjunction with the INTEGRA or
VERSA control panels,
–
for 40 seconds after power-up of the siren.
The command to block/unblock the tamper alarm signaling in connection with
entering/exiting the service mode or the test mode is sent during polling time.