ACU-100 SATEL
23
Depending on the controller operating configuration, the signaling is triggered:
– on activating the output of INTEGRA or VERSA system to which the wireless siren is
assigned. The output is to be suitably programmed.
– on activating the controller input which has been selected as the control one.
7.1 D
ESCRIPTION OF
ASP-105
SIREN FUNCTIONING
The ASP-105 outdoor siren:
– occupies 2 positions on the list of devices supported by the controller (acoustic signaling
and optical signaling separately);
– takes up 2 outputs and 2 zones in the INTEGRA or VERSA alarm system;
– takes up 2 zones and also requires 2 controller inputs to control signaling in the CA-64 or
CA-10 alarm system;
– requires 2 inputs and 2 controller outputs when working in conjunction with other control
panels.
Information on power supply status and tampers is conveyed by means of the alarm system
zones / controller outputs.
The siren allows for independent triggering of optical and acoustic signaling. The command
to trigger the signaling is transmitted by the controller to the siren immediately. Duration of
the acoustic signaling cannot exceed the time programmed for the siren. Duration of the
optical signaling is not limited.
The siren re12 V DC supply. A 6 V 1.2 Ah battery can be used as an backup power
supply source.
Note:
The siren does not test the battery, hence the battery status should be periodically
checked by the service personnel, as part of the maintenance work.
Depending on the controller operating configuration, the loss of +12 V DC voltage will:
– cause violation of the second zone occupied by the siren in the system (communication
through the bus with INTEGRA, VERSA, CA-64 or CA-10 control panels);
– activate the controller LBA output;
– activate the controller output assigned to the optical signaling (the second position
occupied by the siren on the list of devices).
Depending on the controller operating configuration, the low battery will:
– cause violation of the first zone occupied by the siren in the system (communication
through the bus with INTEGRA, VERSA, CA-64 or CA-10 control panels);
– activate the controller LBA output;
– activate the controller output assigned to the acoustic signaling (the first position occupied
by the siren on the list of devices).
7.2 D
ESCRIPTION OF
ASP-205
SIREN FUNCTIONING
Do not leave the ASP-205 siren with its battery inside, if the siren is not installed
in the system. The wireless device which has no communication with the control
panel for more than 10 minutes will consume more energy, thus reducing the
battery life.
The ASP-205 wireless indoor siren:
– occupies 2 positions on the list of devices supported by the controller;
– takes up 2 outputs and 2 zones in the INTEGRA or VERSA alarm system;
– takes up 2 zones and also requires 2 controller inputs to control signaling in the CA-64 or
CA-10 alarm system;