in monitoring the response cycle. If during a consecutive poll a device fails to establish
communication with the controller, the fact is registered and presented as impairment of
communication quality. The test is carried out in the on-line mode, and its results are
visualized as the
Communication quality
in percentage form.
Synchronization
– the ACU-100 controller checks whether other wireless systems are
operating within its range, and if so, it adjusts the response time accordingly.
Synchronization is performed automatically on starting the controller and after each
operation of addition/removal of devices supported by it. Additionally, it can be started
manually with this command.
Supply voltage
– function if the LCD keypad which allows the controller supply voltage level
to be checked. In the D
LOAD
10, D
LOAD
X programs, the information on supply voltage is
provided in on-line mode, with no need for starting any function whatever.
In/Out module tampers
– information on communication of the controller with the ACX-100
input/output expansion modules, available in the D
LOAD
10
program only. Lack of
communication is recognized as the module tamper.
Tamper alarm in partition [Expander tamper]
– this option, available when the controller
works together with the INTEGRA or VERSA control panel, makes it possible to indicate
the partition where alarm will be triggered in the event of controller tamper.
No blocking after 3 tampers
– option available when interacting with the INTEGRA or
VERSA series control panel. The controller generates alarm on opening the tamper
contact. Normally, if 3 consecutive tamper alarms are not cleared, signaling of next
tamper alarms will be blocked, which prevents the same events being repeatedly saved
in the control panel memory. The option allows the blocking to be disabled.
Always active
– this option, available in the D
LOAD
X program, allows the detector to be
permanently switched to active state.
Service end
– this function ends the service mode in the keypad.
12. C
ONFIGURATION OF ADDITIONAL PARAMETERS AND OPTIONS IN
WIRELESS DEVICES
12.1 D
LOAD
X
OR
D
LOAD
10
PROGRAM
Additional parameters and options are to be programmed in the "Configuration" column.
12.1.1 APD-100
detector
For detectors with firmware version 2.01, enter a 2-digit sequence. The first digit relates to
sensitivity (see: Table 10), and the second one – to the pet immunity option (0 – option
disabled, 1 – option enabled). For detectors with older firmware, enter a digit from 1 to 3,
which corresponds to the selected sensitivity (see: Table 10).
Number
Detector sensitivity
1 low
2 medium
3 high
Table 10.
12.1.2 APMD-150
detector
Enter a 3-digit sequence:
1
st
digit
– sensitivity of infrared path: from 1 to 4 (1 – minimum; 4 – maximum),