Two-way wireless system ABAX
ACU-100
42
given in the user menu, T
ROUBLES
submenu, and in the D
LOAD
X program, in the
"Troubles" window.
Tamper state
– this function, available in the LCD keypad connected to the controller, allows
you to check which of the wireless devices are or were tampered with. In the D
LOAD
10
program, all the tamper-related information is given on-line, with no need for calling any
function. In the INTEGRA or VERSA system LCD keypad, as well as in the D
LOAD
X
program, it is possible to check the wireless device/controller for presence of tamper by
using the E
VENTS
function. Additionally, the information on possible tampers of wireless
devices can be found in the D
LOAD
X program in the "Zones state".
Battery status
– function is available in the LCD keypad connected to the controller.
Depending on the type of device, the low battery message may indicate:
– low battery (detectors);
– loss of 12 V DC supply (ASP-105 siren);
– loss of 18 V AC supply (ACX-201 expander);
– discharged battery (ASP-105 siren, ACX-201 expander);
– overload of AUX1 or AUX2 supply output (ACX-201 expander).
In the D
LOAD
10 program, information on the status of battery / power supply / storage
battery / supply outputs is given in on-line mode in the "Battery" column. In the
INTEGRA or VERSA system LCD keypad, information on low batteries and other
troubles is given in the user menu, T
ROUBLES
submenu, and in the D
LOAD
X program, in
the "Troubles" window.
Note:
When low battery status is indicated, replace the battery within 2–3 weeks.
Jamming
– this function, available in the LCD keypad connected to the controller, makes it
possible to check whether the wireless system operation is not jammed by any device,
which emits radio waves on the same frequency. If there was a jamming event,
information is given of the fact, stating how many times and what was its amplitude. In
the D
LOAD
10 program all the information on jamming is given in on-line mode, with no
need for calling any function. In the INTEGRA or VERSA system LCD keypad, the
information on possible jamming is given in the user menu, T
ROUBLES
submenu, and in
the D
LOAD
X program, in the "Troubles" window.
Test mode
– activation of the test mode makes all the wireless devices indicate
communication with the controller by blinking LEDs. Detectors inform on violations and
tampers, using the LEDs. In the normal operating mode of the wireless devices, the
signaling on LEDs is "off" for energy-saving considerations. When in the test mode, the
tamper alarm signaling in sirens is disabled. After exiting the test mode, its actual
termination will take place at the next response period. The test mode will be
automatically exited 30 minutes after:
– it is started through the D
LOAD
X program. If the W
IRELESS DEVICES
window is opened
during this time in the D
LOAD
X program, the test mode duration will be extended (the
30-minute countdown will run from closing the window),
– termination of the service mode in the INTEGRA or VERSA control panel or the
keypad connected to the controller,
– closing the D
LOAD
10 program.
Note:
According to requirements of the EN50131 standard, the level of radio signals sent by
wireless devices is reduced during the test mode operation.
Clear memory
– this command will erase the memory, where information on tampers of
wireless devices, low battery, and jamming is stored.
Restart communication test
– the command, available in the D
LOAD
10 and D
LOAD
X
programs only, which resets the
communication test
. The communication test consists