ACU-100 SATEL
31
information from the wireless devices assigned to these outputs. Connecting the ACU-100
controller to the CA-10 control panel at the same time by means of communication bus and
control panel zones will enable the system to be expanded by up to 14 wireless zones.
COM
TMP
COM
+
12V
I
TMP
TMP
A
RS485
B
C
L
K
DA
T
COM
TPR CON JAM
L
BA OUT1OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 COM AR1 AR2 AR3 AR4
ACU
-
100
COM
+
KPD DATA C
L
K1 C
L
K2 C
L
K3 C
L
K4 COM Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8
OUT5
OUT6
COM
+
12V
COM OUT4
CA
-
10
CLK
DAT
OUT1
OUT2
AR1
AR2
Fig. 12. Example of connecting the ACU-100 controller to the CA-10 control panel.
Fig. 12 shows an example of configuration of the ACU-100 controller interacting with the
CA-10 control panel. One keypad is connected to the control panel, therefore the CLK
controller terminal is connected to the CLK2 panel terminal. The zones made available by the
ACU-100 controller to the control panel by means of the communication bus have in the
security system numbers from 11 to 16 (controller outputs from 11 to 16). These zones
should be programmed in the control panel as 2EOL/NO type. The controller outputs OUT1
and OUT2 have been connected, respectively, to the control panel zones Z1 and Z2 (thus,
the total number of wireless zones in the system will amount to 8).The control panel zones to
which the controller outputs have been connected should be configured as NO type. Still
available are the control panel zones from Z3 to Z8. You can connect to them wire-operated
devices or consecutive controller outputs as well as wireless devices assigned to them. The
OUT5 control panel low-current output has been programmed as type 35: P
OWER SUPPLY ON
ARMED MODE
and connected to the
AR1 controller control input. This input switches the
wireless detectors from passive to active state, and vice versa. The OUT6 control panel low-
current output has been programmed as type 01: B
URGLARY ALARM
and connected to the
AR2
controller control input. This input triggers the wireless siren. In the presented example, the
controller information outputs (TPR, CON, JAM, LBA) have remained unconnected. These