Two-way wireless system ABAX
ACU-100
44
2
nd
digit
– sensitivity of microwave path: from 1 to 8 (1 – minimum; 8 – maximum),
3
rd
digit
– type of operation in the test mode: 0 (signaling violation after motion is sensed by
both detectors), 1 (signaling violation after motion is sensed by infrared detector) or 2
(signaling violation after motion is sensed by microwave detector).
For example, entering the values 4-4-0 means that the infrared sensitivity path has been set
to 4, the microwave sensitivity path also to 4, and in the test mode the detector will signal
violation (the LED will light up) after motion is sensed by both detectors.
12.1.3 AMD-100
and
AMD-101 detectors
Enter the digit 0 (the lower reed switch) or 1 (the side reed switch) to select which of the two
reed switches is to be active.
12.1.4 AMD-102
detector
For the magnetic contact (the first position / the first zone occupied by the AMD-102
detector), enter the digit 0 (the lower reed switch) or 1 (the side reed switch) to select which
of the two reed switches is to be active.
For the roller shutter input (the second position / the second zone occupied by the AMD-102
detector), enter a sequence of two digits:
1
st
digit
– number of pulses: from 1 to 8,
2
nd
digit
– pulse validity: 0 (30 s), 1 (120 s), 2 (240 s) or 3 (unlimited duration – only
switching over the detector from passive into active mode will reset the pulse counter).
For example, entering the values 4-2 means that the zone will be violated after registering
4 pulses, and the maximum time that can elapse between the first and the last pulse can be
240 seconds.
12.1.5 AGD-100
detector
Enter a digit from 1 to 3 which corresponds to the selected sensitivity for the high-frequency
channel (see: Table 10).
12.1.6 AVD-100
detector
For the magnetic contact (the first position / the first zone occupied by the AVD-100 detector),
enter the digit 0 (the lower reed switch) or 1 (the side reed switch) to select which of the two
reed switches is to be active.
For the vibration detector (the second zone occupied by the AVD-100 detector), enter a 2-
digit sequence:
1
st
digit
– sensitivity: from 1 to 8 (1 – minimum; 8 – maximum),
2
nd
digit
– number of pulses: from 0 to 7.
For example, entering the values 4-6 means that sensitivity has been set to 4, and the
number of pulses to 6.
12.1.7 ASD-100
detector
Enter a 3-digit sequence corresponding to the selected parameters, as shown in Table 11.
1st digit
2nd digit
3rd digit
digit
heat sensor
digit
audible signaling
digit
signaling duration
0 disabled 0
none
1 1
minute
1
A1
1
sound type 1
2
3 minutes
2
A2
2
sound type 2
3
6 minutes
3
B
3
sound type 3
4
9 minutes
Table 11.