Two-way wireless system ABAX
ACU-100
20
connected to the controller, or through the D
LOAD
10
program. The control inputs should be
connected to the suitably programmed outputs of the control panel.
5.1.3 Configuration
of
ACX-200 or ACX-201 expander zones/outputs for
ACU-100 controller operation with other control panels
Programming the zones/outputs of the expander is possible by using the keypad connected
to the controller or by means of the D
LOAD
10
program.
It is necessary that operating configuration of the detector connected to the expander be
determined and sensitivity defined for each expander zone. Additionally, the expander zones
should be assigned to the selected controller outputs. Irrespective of how the expander
zones will be programmed, the control panel zones to which the ACU-100 controller outputs
will be connected, are to be configured as NO or NC type (see also section I
NTERACTION WITH
ALARM CONTROL PANELS
).
In the LCD keypad, any changes of the zone type and sensitivity level are to be done by
means of the
CONFIGURATION
function. The
S
and
T
keys make it possible to change the
parameter values. The
W
and
X
keys allow you to move between the top and bottom lines of
the display, i.e. between the parameters to be programmed.
In the D
LOAD
10 program, click in the „Configuration” column on the field referring to the
expander zone for which type and sensitivity are to be programmed. These parameters are
separated by a dash. The first position indicates the zone type. Using the keypad, you can
enter here a digit from the 0 to 5 range, according to Table 5.
Digit
Zone type
0 no
detector
1 NC
2 NO
3 EOL
4 2EOL/NO
5 2EOL/NC
Table 5.
The second position indicates the zone sensitivity. Using the keypad you can enter a value
from the 20ms to 5100ms range. Within the range of 20ms to 140ms, it is possible to enter
values every 20ms (20ms, 40ms, 60ms, etc.). The next value that can be entered is 300ms.
Within the range of 300ms to 5100ms, you can enter values every 200ms (300ms, 500ms,
700ms, etc.). If a number different from the above values is entered, it will be rounded up to
the next supported value (e.g. after entering 301, the next value to be entered is 500ms).
In order to configure the expander outputs, indicate the appropriate ACU-100 control inputs
which will control the expander outputs. The control inputs are to be connected to the suitably
programmed outputs of the alarm control panel.
6. W
IRELESS DETECTORS IN
ABAX
SYSTEM
The wireless detectors send information on violations, tampers, and battery status to the
ACU-100 controller. Two detector operating modes are available:
–
passive mode
– the battery saving mode, in which information on violations and battery
status is sent to the controller exclusively during the response period (see the R
ESPONSE
PERIOD
parameter), only the tamper information being sent immediately. The detectors
can work in the passive mode, when the alarm system is disarmed.
–
active mode
– all information is sent to the controller instantly.