ACU-100 SATEL
29
Fig. 9. Example of setting the DIP-switches.
Fig. 10 shows a configuration example of the ACU-100 controller working together with the
CA-64 control panel. The controller communication bus is connected to the second expander
bus of the control panel. The OUT9 panel low-current output has been programmed as type
42: P
OWER SUPPLY ON ARMED
and connected to the AR1 controller control input. This input is
used to toggle the wireless detectors between their passive and active state. The OUT10
panel low-current output has been programmed as type 1: B
URGLARY ALARM
and connected to
the
AR2 controller control input. This input triggers the wireless siren. In the presented
example, the controller information outputs (CON, JAM, LBA) remain unconnected. They can
be connected to the control panel inputs so as to obtain in this way information on troubles
related to operation of the wireless devices.
COM
TMP
COM
+12V
ITMP
TMP
A
RS485
B
CLK
DA
T
COM
TPR CON JAM LBA OUT1OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 COM AR1 AR2 AR3 AR4
ACU-100
COM
COM EX2 DT2 CK2 Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
Z9
Z10 Z11
Z12 Z13
Z14 Z15
Z16
COM
COM
COM
COM
COM
COM
COM
+12V
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
COM
CK1
CA-64
Fig. 10. Example of connecting the ACU-100 controller to the CA-64 control panel.
Having connected the ACU-100 controller to the control panel, start the expander
identification function in it.
programming:
D
LOAD
10
address:
25
operating mode:
CA-64 control panel