ACU-100 SATEL
27
system first, so as to maintain the continuity of using both the zones and the outputs. Table 7
presents a situation in which the first output of the siren has found itself in position 8, and the
second output in position 9. As a result, 16 outputs have been reserved in the system (the
eight output in the first group of 8 outputs, and the first output in the second group of
8 outputs).
COM
TMP
COM
+12V
ITMP
TMP
A
RS485
B
CLK
DA
T
COM
TPR CON JAM LBA OUT1OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 COM AR1 AR2 AR3 AR4
ACU-100
INTEGRA 64 / INTEGRA 128
COM
+12V
DAT
CLK
Fig. 8. Example of connecting the ACU-100 controller to the INTEGRA control panel.
INTEGRA 64/128
ACU-100
zones
outputs
It.
List of devices
No.
Device
No.
Device
1
detector APD-100
17 APD-100 detector
17 unused/unavailable
2
APD-100 detector
18 APD-100 detector
18 unused/unavailable
3
AMD-100 detector
19 AMD-100 detector
19 unused/unavailable
4
AMD-100 detector
20 AMD-100 detector
20 unused/unavailable
5
AMD-101 detector
21 AMD-101 detector
21 unused/unavailable
6 ^
22
AMD-101
detector
22
unused/unavailable
7
23
unused/unavailable 23
unused/unavailable
8 ASP-105
siren
8
24 ASP-105 siren
24 ASP-105 siren
9
^
25 ASP-105 siren
25 ASP-105 siren
10 26
unused/unavailable 26
unused/unavailable
11 27
unused/unavailable 27
unused/unavailable
12 28
unused/unavailable 28
unused/unavailable
13 29
unused/unavailable 29
unused/unavailable
14 30
unused/unavailable 30
unused/unavailable
15 31
unused/unavailable 31
unused/unavailable
16
8
32 unused/unavailable 32
unused/unavailable
Table 7. An example of incorrect registration of wireless devices. The system must reserve
16 zones and 16 outputs, as well as 2 addresses for devices taking up 8 items. The controller
with address 0 is connected to the first expander bus.