outputs can be connected to the control panel zones so as to obtain in this way information
on problems connected with operation of wireless devices.
10.4 W
IRELESS DEVICE MODULE INTERFACING WITH ANY ALARM CONTROL PANEL
Using the DIP-switches, set the suitable operating mode of the ACU-100 controller, number
of ACX-100 modules which are connected to it, as well as the programming mode.
Fig. 13. Example of setting the DIP-switches.
COM
TMP
COM
+12V
ITMP
TMP
A
RS485
B
CLK
DA
T
COM
TPR CON JAM LBA OUT1OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 COM AR1 AR2 AR3 AR4
ACU-100
OUT5
OUT6
COM
CLK CTL Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
COM OUT2 COM OUT3 COM +KPD DTA
CA-6
OUT1
OUT2
AR1
AR2
OUT5
OUT4
OUT3
TPR
Fig. 14. Example of connecting the ACU-100 controller to the CA-6 control panel.
programming:
keypad
operating mode:
any control panel
number of ACX-100 modules:
3