ACU-100 SATEL
47
12.2.6 AVD-100
detector
After selecting the first position / the first zone occupied by the AVD-100, the
S
and
T
keys
allow you to indicate the active reed switch of the magnetic contact.
After selecting the second position / the second zone occupied by the AVD-100 detector, the
parameters of the vibration detector can be configured. The
W
and
X
keys allow you to
navigate between the parameters and the
S
and
T
keys to modify them. The following
should be programmed:
– sensitivity within the range from 1 to 8 (1 – minimum; 8 – maximum);
– number of pulses within the range from 0 to 7.
12.2.7 ASD-100
detector
The
W
and
X
keys allow you to navigate between the programmable detector parameters,
and the
S
and
T
keys to modify them. The following should be programmed:
– operating mode of the heat detector: you can disable the detector (the symbol displayed)
or select the detection class (A1, A2 or B) acc. to the standard EN 54-5;
– operating mode of the buzzer: you can disable the buzzer (the symbol displayed) or
select one of the three types of sound signaling;
– duration of alarm signaling by the buzzer/LED: 1, 3, 6 or 9 minutes.
12.2.8 ARD-100
detector
The
S
and
T
keys enable sensitivity to be selected within the range from 1 to 16 (1 –
minimum; 16 – maximum).
12.2.9 ATD-100
detector
Use the
W
and
X
keys to navigate between the programmable parameters of the detector.
Use the numeric keys to program the following:
– temperature: a value from the -30° C to 70° C range (with up to 0.5° accuracy) – to enter
the preceding “-” sign, press one of the numeric keys from 3 to 9;
– tolerance: a value from the 0.5° C to 10° C range (with up to 0.5° accuracy);
– threshold type: H (high) or L (low).
12.2.10 ASP-105 siren
After selecting the first position / the first zone occupied by the siren, define the parameters of
acoustic signaling. Use the
W
and
X
keys to navigate between the parameters and the
S
and
T
keys to modify them. The following should be programmed:
– type of acoustic signaling: a choice out of four types is provided;
– maximum duration of signaling: 1, 3, 6 or 9 minutes.
12.2.11 ASP-205 siren
Signaling parameters can be independently selected for both positions / zones occupied by
the siren. Use the
W
and
X
keys to navigate between the parameters and the
S
and
T
keys
to modify them. The following should be programmed:
– operating mode of acoustic signaling: it can be disabled (the symbol displayed) or one
out of three types of acoustic signaling selected;
– maximum duration of signaling: 1, 3, 6 or 9 minutes;
– operating mode of optical signaling: it can be disabled (the symbol displayed) or enabled
(the
symbol displayed). The LCD keypad of INTEGRA system allows you to
enable/disable the signaling by pressing any numerical key (the
S
and
T
keys have no
effect).