![background image](http://html1.mh-extra.com/html/3com/v6100/v6100_user-manual-manual_3139483187.webp)
V6100 and V7122 User Guide
187
ini File Field Name
Web Parameter Name
Valid Range and Description
Password
[Password]
Password used for Basic/Digest authentication process with Proxy /
Registrar.
The default is ‘Default_Passwd’.
Cnonce
[Cnonce]
String used by the SIP Server and client to provide mutual authentication
(free format, i.e., ‘Cnonce = 0a4f113b’).
The default is ‘Default_Cnonce’.
IsRegisterNeeded
[Enable Registration]
0 = Gateway does not register to Proxy/Registrar (default).
1 = Gateway registers to Proxy/Registrar at power up.
The gateway sends a REGISTER request for each channel or
for the entire gateway (according to the parameter
AuthenticationMode).
RegistrarIP
[Registrar IP Address]
IP address and optionally port number of Registrar server.
Enter the IP address in dotted format notation, for example
201.10.8.1:<5080>.
If not specified, the REGISTER request is sent to the primary
Proxy server (see ‘Proxy IP address’ parameter).
When port number is specified, DNS SRV queries aren’t
performed, even if ‘EnableSRVQuery’ is set to 1.
RegistrarName
[Registrar Name]
Registrar domain name.
If specified, the name is used as Request-URI in REGISTER messages.
If isn’t specified (default), the Registrar IP address or Proxy name or Proxy
IP address is used instead.
GWRegistrationName
[Gateway Registration Name]
Defines the user name that is used in From and To headers of REGISTER
messages.
If ‘GWRegistrationName’ isn’t specified (default), the ’Username’ parameter
is used instead.
This parameter is applicable only to a single gateway
registration (AuthenticationMode=1). When the gateway
registers each B-channel separately (AuthenticationMode=0),
the user name is set to the endpoint’s phone number002E
AuthenticationMode
[Authentication Mode]
0 (Per Endpoint) = Registration & Authentication separately for each B-
channel.
1 (Per Gateway) = Single Registration & Authentication for the gateway
(default).
RegistrationTime
[Registration Time]
Defines the time (in seconds) for which registration to a Proxy server is
valid. The value is used in the header ‘Expires‘. In addition, this parameter
defines the time interval between Keep-Alive messages when
EnableProxyKeepAlive = 2 (REGISTER).
Typically a value of 3600 is assigned, for one hour registration.
The gateway resumes registration according to the parameter
RegistrationTimeDivider.
The default is 3600 seconds.
Summary of Contents for V6100
Page 28: ...28 V6100 and V7122 User Guide Reader s Notes...
Page 48: ...48 V6100 and V7122 User Guide Reader s Notes...
Page 72: ...72 V6100 and V7122 User Guide Reader s Notes...
Page 80: ...80 V6100 and V7122 User Guide Reader s Notes...
Page 152: ...152 V6100 and V7122 User Guide Reader s Notes...
Page 262: ...262 V6100 and V7122 User Guide Reader s Notes...
Page 284: ...284 V6100 and V7122 User Guide Reader s Notes...
Page 291: ...V6100 and V7122 User Guide 291 Figure 95 V7122 Startup Process...
Page 324: ...324 V6100 and V7122 User Guide Reader s Notes...
Page 354: ...354 V6100 and V7122 User Guide Reader s Notes...
Page 374: ...374 V6100 and V7122 User Guide Reader s Notes...
Page 382: ...382 V6100 and V7122 User Guide Figure 130 Example of a User Information File Reader s Notes...
Page 392: ...392 V6100 and V7122 User Guide Reader s Notes...
Page 409: ...V6100 and V7122 User Guide 409 Reader s Notes...
Page 413: ...V6100 and V7122 User Guide 413 Reader s Notes...
Page 425: ...V6100 and V7122 User Guide 425 Figure 145 UDP2File Utility Reader s Notes...
Page 431: ...V6100 and V7122 User Guide 431 Reader s Notes...
Page 447: ...V6100 and V7122 User Guide 447 Reader s Notes...
Page 483: ...V6100 and V7122 User Guide 483 Reader s Notes...