Chapter 3 Structure and Principles
Confidential and Proprietary Information of ZTE CORPORATION
21
AUX port enables to monitor the equipment remotely. AUX port
is a DB9 male port (pin). Therefore, it needs to be matched with
the DB9 female port (interpolation). Table 12 shows AUX port
configuration.
T
A B L E
1 2
A
U X
P
O R T
C
O N F I G U R A T I O N S
SMP AUX
Signal
DB9-End
Signal
1 T232DCD
7
RTS
2 T232RX
3
TX
3 T232TX
2
RX
4 T232DTR
6
DSR
5 GND
5
GND
6 T232DSR
4
DTR
7 T232RTS
1
DCD
8
Not
connected
8 Not
connected
9 T232RI
9
RI
10/100/1000Base-T Ethernet interfaces are available on SMNP
front panel. This port is a management port connecting the
system to the background. This interface can serve as an out-
band router NM-port. The features of 10/100/1000Base-T
Ethernet interface are listed in Table 13.
T
A B L E
1 3
E
T H E R N E T
P
O R T
S
P E C I F I C A T I O N S
Port Type
Specifications
100Base-T
In compliance with IEEE 802.3;
RJ45 connector
Category-3, 4 and 5 Unshielded Twisted Pairs (UTP)
Maximum transmission distance: 185m
100/1000Bas
e-T
In compliance with IEEE 802.3;
RJ45 connector
Category-5 Unshielded Twisted Pairs (UTP)
Maximum transmission distance: 100 m
Note:
When the interface is connected with a host, straight-through
network cable is used; when it is connected with a hub, switch or
router, a crossover cable is used.
AUX Port
10/100/1000
Base-T
Ethernet
Interface
Содержание ZXR10 GER
Страница 4: ...This page is intentionally blank ...
Страница 14: ...This page is intentionally blank ...
Страница 22: ......
Страница 24: ......
Страница 140: ......
Страница 206: ......
Страница 232: ......
Страница 248: ......
Страница 294: ......
Страница 326: ......
Страница 386: ......
Страница 407: ...Tables Confidential and Proprietary Information of ZTE CORPORATION 385 Table 426 Debug Ip Msdp Command 358 ...
Страница 408: ......