ZXR10 Alarm Handling Manual
Recommended
Operations
There may be redundant configuration. Please contact ZTE for the
solution.
OAM Alarm
16899
Message No.
16899
Default Severity
Level
5
Alarm Recovery
Available
Alarm Type
QoSAlarm
NM Level
4
Cause
CPU load, namely CPU utilization ratio reaches the set low thresh-
old.
Influence
It may bring to the slow operation response.
Related Alarms
16900, 16901
Recommended
Operations
If the operation with great consumption on cpu is carried out
in short time, then it is normal phenomenon. Commands show
process, show process detail can be used to view CPU utilization.
Alarm Prototype
Description
%s(M) panel %d current CPU load is: %d%
%s(S) panel %d current CPU load is: %d%
The first %s is the CPU type. The first %d is panel number and
the second %d is CPU utilization.
Alarm occured:
An alarm 16899 level 5 occurred at 00:52:07 01/01/2001 UTC sent
by UPC(MPU) 1 %OAM% CPU load exceeds the lowest threshold
NP(M) panel 7 current CPU load is: 80%.
Alarm cleared:
An alarm 16899 level 5 cleared at 00:53:07 01/01/2001 UTC sent
by UPC(MPU) 1 %OAM% CPU load exceeds the lowest threshold
NP(M) panel 7 current CPU load is: 50%.
Alarm Description
CPU load, namely CPU utilization ratio exceeds the set low thresh-
old.
Supported Devices
All.
Appendix
Specification
The platform 4.6.03b and the upgrade versions support this alarm.
Not CE&PTN version.
16900
Message No.
16900
Default Severity
Level
5
44