Chapter 2 Alarm Message
Cause
The current version is in trial run state.
Recommended
Operations
The command updatever activate in privilege mode can be used
to remove the try-running alarm.
Alarm Prototype
Description
Current version is in try-running and activate it please.
Example:
14:28:01 03/21/2008 UTC alarm 16392 occurred %ROS% Current
version is in try-running and please activate it sent by MEC 1.
Alarm Description
The current version is in trial running state and it need to be acti-
vated by users. Or the device reboots automatically after a while.
The remaining time can be viewd by command
show updatever
in privileged mode.
Supported Devices
CE&PTN 6100
CE&PTN 8900
Appendix
Specification
CE&PTN version supports this alarm.
16392
Message No.
16392
Default Severity
Level
5
Alarm Type
CLASS_NOTIFY
NM Level
4
Cause
The current version is the rollback. The reason may be that the
trial run fails when updating the version.
Recommended
Operations
The command updatever activate in privilege mode can be used
to remove the trial run alarm.
Alarm Prototype
Description
Back-version is running now for loading update-version failed
14:27:32 03/21/2008 UTC alarm 16392 occurred %ROS% Back-
version is running now for loading update-version failed sent by
MEC 1
Alarm Description
The current version is the rollback. The reason may be that the
trial run fails when updating the version
Supported Devices
CE&PTN 6100
CE&PTN 6100
Appendix
Specification
CE &PTN version supports this alarm.
16393
Message No.
16393
Default Severity
Level
5
Alarm Recovery
Unavailable
Alarm Type
CLASS_NOTIFY
NM Level
5