Chapter 4 TRAP Messages
The port PoE power supply status type:
disabled 1
searching 2
deliveringPower 3
fault 4
test 5
otherFault 6
pethMainPowerUsageOnNotification
Message
Description
PSE total power of the power supply exceeds power threshold.
Trigger Conditions
1. PSE total power of the power supply exceeds power threshold.
2. The configuration of SNMP related to PoE sending trap is cor-
rect.
Recommended
Operations
N.A.
Bound Variables
pethMainPseGroupIndexPSE device number
OID 1.3.6.1.2.1.105.1.3.1.1.1
pethMainPseConsumptionPowerPSE total power of power supply
OID 1.3.6.1.2.1.105.1.3.1.1.4
pethMainPseUsageThresholdPSE power threshold
OID 1.3.6.1.2.1.105.1.3.1.1.5
pethMainPowerUsageOffNotification
Message
Description
PSE total power of the power supply recovers in the range of power
threshold.
Trigger Conditions
1. PSE total power of the power supply exceeds power threshold
or recovers in the range of power threshold.
2. The configuration of SNMP related to PoE sending trap is cor-
rect.
Recommended
Operations
N.A.
Bound Variables
pethMainPseGroupIndexPSE device number
OID 1.3.6.1.2.1.105.1.3.1.1.1
pethMainPseConsumptionPowerPSE total power of power supply
OID 1.3.6.1.2.1.105.1.3.1.1.4
pethMainPseUsageThresholdPSE power threshold
OID 1.3.6.1.2.1.105.1.3.1.1.5
Confidential and Proprietary Information of ZTE CORPORATION