Default Severity Level
ZXR10 devices alarm level includes the following 8 levels:
�
Severity 1: emergency messages EMERGENCIES, the system
is unusable.
�
Severity 2: alert messages ALERTS. Magnitude malfunction
appears in the system and immediate action is needed.
�
Severity 3: critical messages CRITICAL. Emergency condition
appears.
�
Severity 4: error messages ERRORS. Error condition appears.
�
Severity 5:
warning messages WARNINGS. The system
prompts that warnings appear.
�
Severity 6: notification messages NOTIFICATIONS. The normal
but significant event information that the system notifies to
each part and records.
�
Severity 7: informational messages INFORMATIONAL. It is
only an informational message.
�
Severity 8: debugging messages DEBUGGING. It is the re-
spondse information type when the administrator debugs the
system or network .
Alarm level includes the default and actual level. The default
level is the original alarm level and it is fixed. Users can not
modify it. The actual alarm level is the one used in the process
of device running which is equal to the default level. Users can
modify it using the command
alarm level-change
<
alarm-co
de
><
level
>. Only alarm levels 4–8 can be modified.
Alarm Recovery
Alarm recovery includes "available" and "unavailable". "available"
means that a prompt will appear when this alarm is deleted.
"unavailable" means that there is no prompt when this alarm is
deleted.
Alarm Type
Alarm type includes the following six categories.
�
"CommunicationAlarm"
�
"ProcessingErrorAlarm"
�
"QOSAlarm"
�
"EquipmentAlarm"
�
"EnvironmentalAlarm"
�
"OMSAlarm"
2