Chapter 2 Alarm Message
Alarm Prototype
Description
Alarm Occurred
%s(M) panel %d exceeds memory rate is: %3.3f%% under the
alarm threshold is %d%%
%s(S) panel %d exceeds memory rate is: %3.3f%% under the
alarm threshold is %d%%
Alarm Cleared
%s(M) panel %d current memory rate is: %3.3f%% under the
alarm threshold is %d%%
%s(S) panel %d current memory rate is: %3.3f%% under the
alarm threshold is %d%%
The first %s is CPU type, the first %d is CPU SlotNo, the first %f is
the current CPU utilization and the second %d is the set memory
utilization threshold.
An alarm 66 level 5 occurred at 01:47:50 01/28/2001 UTC sent
by UPC(MPU) 2 %ENVIRONMENT% SP(M) panel 1 current memory
rate is: 40.562% exceeds the alarm threshold is 2%
An alarm 66 level 5 cleared at 01:48:20 01/28/2001 UTC sent by
UPC(MPU) 2 %ENVIRONMENT% RP(M) panel 2 current memory
rate is: 40.084% under the alarm threshold is 60%
Alarm Description
CPU utilization exceeds the set memory utilization threshold. It is
60% by default.
Supported Devices
T128/T64,T600/T1200
Appendix
Specification
N.A.
67
Message No.
67
Default Severity
Level
5
Alarm Recovery
Available
Alarm Type
Environmental Alarm
NM Level
4
Cause
The remote temperature is lower than the set remote lower thresh-
old of the board.
The command used to set threshold for equipment temperature:
temper-threshold UPC master local lowthreshold -20 first-high-
threshold 55 second-highthreshold 90.
Related Alarms
68, 69
Recommended
Operations
Increase the environment temperature of the equipment if neces-
sary.
Alarm Prototype
Description
Alarm Occurred
%s Panel %d Current remote temperature is %d
℃
/%dF,under the
low threshold(%d
℃
/%dF)
Alarm Cleared
%s Panel %d Current remote temperature is %d
℃
/%dF,exceeds
the low threshold(%d
℃
/%dF)