Chapter 2 Alarm Message
21774
Message No.
21774
Alarm Type
ProcessingErrorAlarm
NM Level
5
Cause
Because one securityaccess item is set to ON state. Multiple secu-
rity access entries are in ON state on a non-stack master device.
Influence
The item in ON state currently will not take effect when the alarm
occurs.
Recommended
Operations
Reduce the number of entries whose state are ON, for which we
can set the states of entries not needed to OFF and re-set the state
of specific entry to ON.
Alarm Prototype
Description
“Too many security access entities are enabled”
For example:
An alarm 21774 level 5 occurred at 00:08:59
01/01/2001 UTC sent by Stack Slave DevId 2 %ACL% Too many
security access entities are enabled
Alarm Description
Multiple security access entries are in ON state on a non-stack
master device.
Supported Devices
ZXR10 59/52 series.
21775
Message No.
21775
Alarm Type
ProcessingErrorAlarm
NM Level
5
Cause
Error occurs when doing Securityaccess operation. It's a prompt
used when operation error occurs on a non-stack master device in
stack system.
Influence
The current operation is invalid.
Recommended
Operations
Retry; delete partial entries whose states are ON or set them to
OFF and retry
Alarm Prototype
Description
“Security access bind ip and mac error at driver”
Alarm occured:
An alarm 21775 level 5 occurred at 00:08:59 01/01/2001 UTC
sent by Stack Slave DevId 2 %ACL% Security access bind ip and
mac error at driver.
Alarm Description
The drive operation is error on a non-stack master device.
Supported Devices
ZXR10 59/52 series.
21776
Message No.
21776
Default Severity
Level
5
Confidential and Proprietary Information of ZTE CORPORATION
93