Chapter 2 Alarm Message
%s Panel %d Current local temperature is %d
℃
/%dF,under the
first high threshold(%d
℃
/%dF)
The first %s is the board type, the first %d is the panel number
of the board, the second %d is the centigrade temperature of the
board, the third %d is the Fahrenheit temperature of board, the
fourth %d is the centigrade temperature of the set threshold and
the fifth %d is the Fahrenheit temperature of the set threshold.
Alarm Occurred
%s Current local temperature is %d
℃
/%dF,exceeds the first high
threshold(%d
℃
/%dF)
Alarm Cleared
%s Current local temperature is %d
℃
/%dF,under the first high
threshold(%d
℃
/%dF)
The first %s is the board type and is fixed to BIC board. There is
no panel number on BIC board, so the display format is different
from other board: the first %d is the centigrade temperature of
the board, the second %d is the Fahrenheit temperature of board,
the third %d is the centigrade temperature of the set threshold and
the fourth %d is the Fahrenheit temperature of the set threshold.
An alarm 64 level 5 occurred at 01:58:30 01/28/2001 UTC sent
by UPC(MPU) 2 %ENVIRONMENT% SFC Panel 1 Current local tem-
perature is 33
℃
/91F,exceeds the first high threshold(30
℃
/86F)
An alarm 64 level 5 cleared at 01:59:20 01/28/2001 UTC sent by
UPC(MPU) 2 %ENVIRONMENT% SFC Panel 1 Current local tem-
perature is 33
℃
/91F,under the first high threshold(55
℃
/131F)
Alarm Description
Board temperature is higher than the set first-high temperature
threshold.
Supported Devices
T128/T64,T600/T1200
Appendix
Specification
N.A.
65
Message No.
65
Default Severity
Level
5
Alarm Recovery
Available
Alarm Type
Environmental Alarm
NM Level
3
Cause
Board temperature is higher than the set second-high temperature
threshold.
The command used to set threshold for equipment temperature is:
temper-threshold UPC master local lowthreshold -20 first-high-
threshold 55 second-highthreshold 90
Related Alarms
63, 64
Recommended
Operations
Decrease board temperature if necessary. Decrease the environ-
ment temperature of the equipment by the fan heat dissipation.
Stop using the board if the temperature is too high.
Confidential and Proprietary Information of ZTE CORPORATION
11