ZXR10 Alarm Handling Manual
Binding variables
None.
warmStart
Information
Description
The trap is sent when it reloads map start during system operation.
Triggering Criteria
1. System applies reload command to reload map initialization or
main/standby switchover.
2. The relevant configuration for SNMP sending trap is correct.
Recommended
Operations
None.
Binding variables
None.
authenticationFailure
Information
Description
The trap is sent when user password authentication is failed while
SNMP v2 version is used to connect the equipment SNMP NMS.
Triggering Criteria
1. The user name and password are mismatched when SNMP v2
is used for accessing equipment.
2. The relevant configuration for SNMP sending trap is correct.
Recommended
Operations
Please check whether any equipment administrator is accessing
the equipment; if it is, please check whether the user name and
password are consistent with the relevant configuration on the
equipment; if not, please check whether anybody is trying to mon-
itor the equipment.
Binding variables
None.
linkUp
Information
Description
The trap is sent when the interface changes from down to up (up
in both the management status and operation status).
Triggering Criteria
1. The interface management and operation status both are in
up.
2. The relevant configuration for SNMP sending trap is correct.
Recommended
Operations
None.
Binding variables
ifIndex (interface index)
OID: 1.3.6.1.2.1.2.2.1.1
ifAdminStatus (interface managing status)
OID: 1.3.6.1.2.1.2.2.1.7
ifOperStatus (interface operating status)
OID: 1.3.6.1.2.1.2.2.1.8
258
Confidential and Proprietary Information of ZTE CORPORATION