Chapter 2 Alarm Message
Default Severity
Level
5
Cause
Too many ACL regulation is applied in one line card.
Recommended
Operations
If alarm disappears after a while, then it means that instant mem-
ory occupancy is too much. It makes no influence. If alarm sus-
tains, check whether memory occupancy reaches the maximum
and the configuration information reaches or exceeds the thresh-
old. If the memory occupancy reaches the threshold, please up-
grade the device. Or contact with ZTE corporation.
18794
Message No.
18794
Default Severity
Level
4
Cause
ACL module of NPC fails to dispose message.
Recommended
Operations
This alarm is a prompt. It is usually caused by instant busyness of
interior communication. This alarm disappears later. If the alarm
continues, please contact with ZTE Corporation.
18832
Message No.
18832
Default Severity
Level
6
Alarm Recovery
Unavailable
Alarm Type
ProcessingErrorAlarm
NM Level
5
Cause
When LSP pings TE tunnel, the setting to option Size is so large
that the size of LSP ping packet is larger than MTU of outgoing in-
terface, where packet segmentation is needed. But packet cannot
be segmented when LSP pings TE tunnel.
Influence
Fails to send LspPing packet and prints "Q". LspPing can not get
through.
Recommended
Operations
Reduce the setting to option Size in LSP PING TE tunnel.
Alarm Prototype
Description
Alarm occured
02:09:51 11/09/2098 UTC alarm 18832 occurred %IP% Operation
failed while fragmentize RSVP datagram sent by UPC(RPU) 1
Alarm Description
Because the set option size is too big, the LspPing packet is larger
than the MTU of the outgoing interface. RSVP packet cannot be
segmented when LSP pings TE tunnel.
Supported Devices
T128, T1200