ZXR10 Alarm Handling Manual
Cause
A prompt appears: succeed to download and upgrade the version,
but fail to write the upgrade rollback.
Recommended
Operations
No.
Alarm Prototype
Description
Downloading update-version file successfully but setting the flag
failed
Example:
14:29:01 03/21/2008 UTC alarm 16392 occurred %ROS% Down-
loading update-version file successfully but setting the flag failed
sent by MEC 1
Alarm Description
A prompt appears: succeed to download and upgrade the version,
but fail to write the upgrade rollback.
Supported Devices
CE&PTN 6100
CE&PTN 8900
Appendix
Specification
CE&PTN version supports this alarm.
16394
Message No.
16394
Default Severity
Level
5
Alarm Recovery
Available
Alarm Type
Equipment Alarm
NM Level
5
Cause
Alarm occurred
Users configure the device again after plugging the backplane. The
backplan backup does not complete.
Alarm cleared
The backplane finishes the backup for the main board. The back-
plane can work instead of the main board.
Influence
The backplane can not work instead of the main board.
Recommended
Operations
Wait for a while to see whether the alarm recovers.
Or check
whether the backplane backup the data on the main board.
Alarm Prototype
Description
Alarm occurred
Slave is not a copy of master. Slave board can not substitute for
master board.
14:50:22 08/20/2008 green alarm 16394 occurred %ROS% Slave
is copying of master. Slave board can not substitute for master
board. sent by UPC(MPU) 2
Alarm cleared
Slave is a copy of master. Slave board can substitute for master
board.
14:59:17 08/20/2008 green alarm 16394 cleared %ROS% Slave
is a copy of master. Slave board can substitute for master board.
sent by UPC(MPU) 2.
40