ZXR10 Alarm Handling Manual
Appendix
Specification
N.A
310
Message No.
310
Default Severity
Level
6
Alarm Recovery
Unavailable
Alarm Type
Equipment Alarm
NM Level
5
Cause
The hardware is instable. Fails to write to the register in interface
board initialization or the platform command configuration.
Influence
The interface board or the line card can not work normally. The
platform command configuration fails.
Related Alarms
No.
Recommended
Operations
Plug the interface board or the line card again. If the malfunction
still exists, then contact ZTE customer service personnel to check
whether the interface board or the line card is abnormal.
Alarm Prototype
Description
write register failed:baseaddr = 0x%08x ,offset =0x%4x
%08x: the base address
%04x: the offset address
Example:
14:17:56 05/20/2008 UTC alarm 303 occurred %Board% write
register failed:baseaddr = 0xC6002000 ,offset =0x0006 sent by
NPC 2
Alarm Description
Alarm appears when the line card fails to modify the register.
Alarm may also appear when failing to write to the register in
interface board initialization or the platform command configura-
tion. It is used to diagnose the hardware abnormity.
Supported Devices
T64E/T128, T600/T1200
Appendix
Specification
N.A
311
Message No.
311
Default Severity
Level
5
Alarm Recovery
Unavailable
Alarm Type
Equipment Alarm
NM Level
5
Cause
The board link forwarding is abnormal.
Influence
The corresponding hardware reboots.
Related Alarms
No.
26
Confidential and Proprietary Information of ZTE CORPORATION