Chapter 2 Alarm Message
Alarm Prototype
Description
Alarm Occurred
Fan error reason %s
Alarm Recovered:
Fan recover: %s
%s cause
�
The 3 types of new rack alarms are as follows( only for new
rack).
i.
The fan data line isn't plugged into the BIC board. If none
of the 3 power modules are working, it implies that the
power and the fan are not plugged well.
14:51:08 08/14/2008 UTC alarm 80 occurred Fan error,
reason: The fan data line isn't plugged into the bic board
sent by UPC(MPU) 1
ii. Current Trunk Top Fan fail to work
14:44:38 08/14/2008 UTC alarm 80 occurred Fan er-
ror, reason: Current Trunk Top Fan fail to work sent by
UPC(MPU) 1
iii. Current Trunk Bottom Fan fail to work
15:51:32 08/14/2008 UTC alarm 80 occurred Fan error,
reason: Current Trunk Bottom Fan fail to work sent by
UPC(MPU) 1
�
The 4 types of old rack alarms are as follows(only for old rack).
i.
The fan data line isn't plugged into the BIC board. If all the
fans are not working, it implies that the line of the fan is
not plugged well.
14:51:08 08/14/2008 UTC alarm 80 occurred Fan error,
reason: The fan data line isn't plugged into the bic board
sent by UPC(MPU) 1
ii. Current Trunk Top Fan Num …..fail to work
One or two of the 8 fans work abnormally. The abnormal
fan number is behind Num. For example, Num 3 5.
14:53:08 08/14/2008 UTC alarm 80 occurred Fan error,
reason: Current Trunk Top Fan Num 3 4 7 8 fail to work
sent by UPC(MPU) 1
iii. Current Trunk Bottom Fan Num….. fail to work
One or two of the 8 fans work abnormally. The abnormal
fan number is behind Num. For example, Num 3 5.
14:55:08 08/14/2008 UTC alarm 80 occurred Fan error,
reason: Current Trunk Bottom Fan Num 3 4 7 8 fail to work
sent by UPC(MPU) 1
iv. Current Cabinet Top Fan Num …..fail to work
One or two of the 6 fans work abnormally. The abnormal
fan number is behind Num. For example, Num 3 5.
14:57:38 08/14/2008 UTC alarm 80 occurred Fan error,
reason: Current Cabinet Top Fan Num 3 4 fail to work sent
by UPC(MPU) 1