ZXR10 Alarm Handling Manual
Recommended
Operations
Decrease the board temperature if necessary. Decrease the envi-
ronment temperature of the equipment by the fan heat dissipation.
If the temperature is too high, stop using the board.
Alarm Prototype
Description
Alarm Occurred
%s Panel %d Current remote temperature is %d
℃
/%dF,exceeds
the second high threshold(%d
℃
/%dF)
Alarm Cleared
%s Panel %d Current remote temperature is %d
℃
/%dF,under the
second high threshold(%d
℃
/%dF)
The first %s is the board type, the first %d is the panel number
of the board, the second %d is the centigrade temperature of the
board, the third %d is the Fahrenheit temperature of board, the
fourth %d is the centigrade temperature of the set threshold and
the fifth %d is the Fahrenheit temperature of the set threshold.
Alarm Occurred
%s Current remote temperature is %d
℃
/%dF,exceeds the second
high threshold(%d
℃
/%dF)
Alarm Cleared
%s Current remote temperature is %d
℃
/%dF,under the second
high threshold(%d
℃
/%dF)
The first %s is the board type and is fixed to BIC board. There is
no panel number on BIC board, so the display format is different
from other board: the first %d is the centigrade temperature of
the board, the second %d is the Fahrenheit temperature of board,
the third %d is the centigrade temperature of the set threshold and
the fourth %d is the Fahrenheit temperature of the set threshold.
An alarm 69 level 5 occurred at 02:02:40 01/28/2001 UTC
sent by UPC(MPU) 2 %ENVIRONMENT% SFC Panel 1 Current
remote temperature is 51
℃
/123F,exceeds the second high thresh-
old(50
℃
/122F)
An alarm 69 level 5 cleared at 02:02:50 01/28/2001 UTC
sent by UPC(MPU) 2 %ENVIRONMENT% SFC Panel 1 Current
remote temperature is 51
℃
/123F,under the second high thresh-
old(100
℃
/212F)
Alarm Description
The remote temperature is higher than the set remote second-high
threshold of the board.
Supported Devices
T128/T64, T600/T1200
Appendix
Specification
N.A.
73
Message No.
73
Default Severity
Level
5
Alarm Recovery
Available
Alarm Type
Environmental Alarm
NM Level
4
16
Confidential and Proprietary Information of ZTE CORPORATION