Chapter 2 Alarm Message
Cause
The number that netflow configures on the line card exceeds the
upper limit specified by system.
The command of sampling rate of configured interface is :
netf
low-sample-rate
{
ingress
|
egress
}{
unicast
|
multicast
|
mpls
|{
aacll
<
acl name
>}}<
1~65535
> , at global configura-
tion mode.
Influence
The sampling configuration that exceeds threshold number can’t
take effect.
Recommended
Operations
Delete the Netflow sample configuration that exceeds the limit.
Use the
no netflow-sample-rate
{
ingress
|
egress
}{
unicast
|
multicast
|
mpls
|{
aacll
<
acl name
>}} command to delete
configuration of interface.
Alarm Description
Prototype
%s(M) panel %d the number of netflow configuration exceeds the
limit
%s(S) panel %d the number of netflow configuration exceeds the
limit
The first %s: cpu typethe first %d: panel number
Example:
An alarm 29960 level 4 occurred at 09:44:55 11/29/2008 UTC sent
by NPC 2 %MIX% The number of netflow configuration exceeds the
limit
Alarm Description
The number that netflow configures on the line card exceeds the
upper limit specified by system.
Supported Devices
T128T1200 (This alarm can be available from V4.8.22.)
BFD alarm
30208
Message No.
30208
Default Severity
Level
5
Cause
The upper-layer application asks for establishing BFD session. It
is the prompt when BFD requests the connection.
Recommended
Operations
It is a prompt. There is no need to care about it.
Alarm Prototype
Description
BFD application prompt for LDP LSP:
00:02:16 02/08/2002 UTC alarm 30208 occurred %BFD% Session
[LDP BFD For FEC 10.40.64.121] is CONNECT on interface fei_1/1
BFD application prompt for RSVP LSP:
00:02:16 02/08/2002 UTC alarm 30208 occurred %BFD% Session
[RSVP BFD For tunnel1] is CONNECT on interface fei_1/1
The prompt for other application:
Confidential and Proprietary Information of ZTE CORPORATION
125