ZXR10 Alarm Handling Manual
Supported Devices
T64/T1200, T600/T1200.
Appendix
Specification
N.A.
301
Message No.
301
Default Severity
Level
6
Alarm Recovery
Unavailable
Alarm Type
Equipment Alarm
NM Level
5
Cause
Abnormality of NPCT line card will lead to interruption of switch
network reset, which further causes the repeat reset of switch
network and thus normal line cards in other slots will fail to send
packets normally. To solve this problem, we give a limit to reset
times. If the times of switch network reset caused by abnormal
line card exceed this threshold, only alarm will be prompted and
switch network will not be reset.
Influence
The linecard with malfunction can not work normally. There is no
influence on other linecards.
Related Alarms
No.
Recommended
Operations
Wait for engineer from customer service department to deal with
the fault line card.
Alarm Prototype
Description
Pannel %d NPC resets switch module over limit times
%d line card slot number
11:02:34 03/21/2008 UTC alarm 301 occurred Pannel 5 npc resets
switch module over limit times. sent by UPC(MPU) 1
Alarm Description
The times of SFU reset caused by abnormal line card exceed this
threshold.
Supported Devices
T64E/T128
Appendix
Specification
N.A.
302
Message No.
302
Default Severity
Level
6
Alarm Recovery
Unavailable
Alarm Type
Equipment Alarm
NM Level
5
Cause
Abnormality of
NPCT
line card will lead to failure of
SFC
syn-
chronization. In case synchronization loss still exists for switch
chip on
SFC
after it resets repeatedly for 30 times, master/slave
switchover of
SFC
will occur and alarm is sent out.