ZXR10 Alarm Handling Manual
Appendix
Specification
N.A.
POE Alarm
30720
Message No.
30720
Default Security
Level
6
Alarm Recovery
None
Alarm Type
SoftProtocolAlarm
NM Level
5
Cause
PSE disables POE function because of over-temperature on the
switch; PSE recovers POE function because of temperature recov-
ers; PSE total power of the power supply exceeds power threshold
or recovers in the range of power threshold.
Influence
Cancel POE function due to high temperature; PSE is made not to
supply power because the total power of the power supply exceeds
power threshold.
Recommended
Operations
Check if the temperature of environment where switch is in is too
high.
Alarm Description
Prototype
Disable POE function because that the whole PSE is over-temper-
ature on the switch.
Disable poe function of the pse %d because of over-temperature
on the switch
Example:
09:40:10 11/13/2008 UTC alarm 30721 occurred %POE% Dis-
able poe function of the pse 1 because of over-temperature on the
switch sent by MEC 1
PSE total power of the power supply exceeds power threshold or
recovers in the range of power threshold.
The usage power (%dw) is below the PSE threshold (%dw) on pse
%d
The first %d: PSE total power of the power supply
The second %d: PSE power threshold.
The third %d: PSE device number.
The usage power (%dw) is above the PSE threshold (%dw) on pse
%d
The first %d: PSE total power of the power supply
The second %d: PSE power threshold.
The third %d: PSE device number.
Example:
132
Confidential and Proprietary Information of ZTE CORPORATION