ZXMW NR8250 Alarm and Notification Handling Reference
l
RCU 0X30XX
l
RTU 0X91XX
l
RMU 0X92XX
l
PM 0X37XX
2.
Turn on the board's power supply.
2.1.2 1002 Board not in position
Alarm Property
l
Alarm Code: 1002
l
Alarm Information: This alarm is reported when the board is configured in the network
management system but is not inserted in the actual slot.
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
The board cannot bear any service.
Possible Causes
1.
The board is configured in a slot on the Local Maintenance Terminal (
) but not
actually inserted in that slot.
2.
The board is configured in a slot on the LMT but not tightly inserted in that slot.
3.
The board is configured in a slot on the LMT but the connecting part is physically
damaged.
Handling Procedure
1.
Check whether the board is inserted into the slot.
l
If yes, go to step 2.
l
If no, insert the board.
2.
Pull out and plug the board into the slot. If the alarm persists, go to step 3.
3.
Replace the shelf.
2.1.3 1004 Board not configured
Alarm Property
l
Alarm Code: 1004
l
Alarm Information: This alarm is reported when the board is configured in the network
management system but is not inserted in the actual slot.
2-2
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential