ZXMW NR8250 Alarm and Notification Handling Reference
Sub-code Description
None
Effect on the System
The system clock PLL cannot be locked properly when the 1588 reference clock source
is taken as the system reference clock source. The system performs changeover to other
reference clock source through the clock protection function.
Possible Causes
l
The local clock is faulty.
l
The 1588 Master clock at the remote end is faulty.
Handling Procedure
1.
Reset the RCUB board and check whether the alarm is cleared. If no, go to step 2.
2.
Replace the RCUB board.
3.
Ensure that the 1588 Master clock at the remote end operates properly.
2.1.23 134317741 Loopback state in IF or modem port
Alarm Property
l
Alarm Code: 134317741
l
Alarm Information: The alarm is reported if loopback is performed at the radio link
port, that is, when the port on MU is in the loopback status (IF/modulation and
demodulation).
l
Alarm Level: Major
l
Alarm Type: Equipment Alarm
Sub-code Description
l
Sub-code 2. Setting modulation and demodulation loopback;
l
Sub-code 4. Setting IF loopback.
Effect on the System
The traffic is interrupted when the radio port is in the loopback status.
Possible Causes
1.
The loopback function is enabled for testing or maintenance.
2.
The board that reports the alarm is faulty.
Handling Procedure
1.
Check whether loopback is set for test or maintenance.
2-18
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential