ZXMW NR8250 Alarm and Notification Handling Reference
Effect on the System
The lightning protector fails.
Possible Causes
1.
The lightning protector is damaged.
2.
The lightning protector's base is of bad contact.
3.
The lightning protector's detecting cable is disconnected or of bad contact.
4.
The monitoring unit's socket is of bad contact or disconnected.
5.
The monitoring unit is faulty.
Handling Procedure
1.
The lightning protector is damaged. Replace the lightning protector;
2.
Check whether the lightning protector's air break switch is closed;
3.
Check whether the lightning protector's base is of bad contact;
4.
Check whether the contact of the lightnring unit is faulty.
5.
Check the monitoring unit's connection;
6.
Replace the monitoring unit.
2.1.29 9005 AC Under-Volt
Alarm Property
l
Alarm Code: 9005
l
Alarm Information: The AC input phase voltage is lower than Phase.OverVolt.
l
Alarm Level: Minor
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
The load capacity of the power supply is influenced, which also affects the normal power
supply for the base station.
Possible Causes
1.
The AC input voltage is low.
2.
The AC under-voltage value of the monitoring unit is set too high.
3.
The AC transducer's connection is faulty or the transducer is damaged.
4.
The monitoring unit's socket is of bad contact or disconnected.
5.
The monitoring unit is faulty.
2-22
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential