ZXMW NR8250 Alarm and Notification Handling Reference
l
Alarm Level: Minor
l
Alarm Type: Environment Alarm
Sub-code Description
None
Effect on the System
The power to the overcurrent board is turned off and the services carried by this board are
completely interrupted.
Possible Causes
The MP current status of the PM board's load is checked periodically. If over-current is
detected, this alarm is reported.
Handling Procedure
1.
Remove and insert the corresponding board;
2.
Replace the corresponding board;
3.
Replace PM board;
4.
Replace the backplane.
2.4.17 405 PP overcurrented
Alarm Property
l
Alarm Code: 405
l
Alarm Information: This alarm is reported when the PP current is out of range and
cleared when the current becomes normal.
l
Alarm Level: Minor
l
Alarm Type: Environment Alarm
Sub-code Description
None
Effect on the System
The power to the over-current board is turned off and the services provided by this board
are interrupted.
Possible Causes
The PP current status of the PM board's load is checked periodically. If over-current is
detected, this alarm is reported.
2-78
SJ-20111008094748-008|2012–05–30 (R1.1)