ZXMW NR8250 Alarm and Notification Handling Reference

2.4.3 134243761 MSTP port ROOT Guard

Alarm Property

l

Alarm Code: 134243761

l

Alarm Information: The alarm is reported if the port is blocked due to the ROOT Guard

function.

l

Alarm Level: Major

l

Alarm Type: Environment Alarm

Sub-code Description

None

Effect on the System

The port is blocked for some time.

Possible Causes

The port configured with ROOT Guard function receives a high-priority configuration

message.

Handling Procedure

Check where the high-level priority BPDU packet comes from, whether the port should be

configured with ROOT Guard function, whether there are network attacks, and whether

the configuration such as bridge priority is correct.

1.

Check whether the bridge whether the port is located is a root bridge.

l

If yes, go to step 2.

l

If no, delete the ROOT protection configuration of the port.

2.

Check whether the expected root bridge does not actually serve as the root due to

incorrect network bridge configuration, for example, incorrect network bridge priority.

l

If yes, modify the configuration.

l

If no, go to step 3.

3.

Find out the source of the packets with higher priority and check whether network

attack exists. If yes, contact the network engineer.

2.4.4 134257728 IDU overheated

Alarm Property

l

Alarm Code: 134257728

l

Alarm Information: The alarm is reported if the working temperature of a board

exceeds the upper limit (80 degree Celsius).

l

Alarm Level: Warning

l

Alarm Type: Environment Alarm

2-70

SJ-20111008094748-008|2012–05–30 (R1.1)

ZTE Proprietary and Confidential

Содержание ZXMW NR8250

Страница 1: ...sion System Alarm and Notification Handling Reference Version V2 00 ZTE CORPORATION NO 55 Hi tech Road South ShenZhen P R China Postcode 518057 Tel 86 755 26771900 Fax 86 755 26770801 URL http ensupport zte com cn E mail support zte com cn ...

Страница 2: ...ringement ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document Except as expressly provided in any written license between ZTE CORPORATION and its licensee the us...

Страница 3: ...t Alarm 2 1 2 1 1 1001 Board powered off 2 1 2 1 2 1002 Board not in position 2 2 2 1 3 1004 Board not configured 2 2 2 1 4 134217728 Clock reference source lost 2 3 2 1 5 134217729 SNTP based time calibration failure 2 4 2 1 6 134217730 RTC clock alarm 2 5 2 1 7 134217735 Clock module was in fault 2 6 2 1 8 134218739 CPU overload 2 6 2 1 9 134218747 RPUA powered off 2 7 2 1 10 134237737 MS EXC 2 ...

Страница 4: ... 28 9004 SPD D Broken 2 21 2 1 29 9005 AC Under Volt 2 22 2 1 30 9006 AC Over Volt 2 23 2 1 31 9007 AC Current Over 2 24 2 2 Communication Alarm 2 24 2 2 1 134217734 ODU level exceeded 2 24 2 2 2 134217736 UAS alarm at air interface 2 25 2 2 3 134217737 UAS alarm of MS 2 26 2 2 4 134217738 UAS alarm of RS 2 26 2 2 5 134237729 RS LOS 2 27 2 2 6 134237731 E1 LOS 2 28 2 2 7 134237733 RS LOF 2 29 2 2 ...

Страница 5: ...threshold 2 55 2 2 40 134243758 Link delay jitter exceeding the threshold 2 55 2 2 41 134243769 EFM local link fault 2 56 2 2 42 134243770 EFM remote link fault 2 56 2 2 43 134243771 EFM discovery process failure 2 57 2 2 44 134243776 EFM local link lost 2 58 2 2 45 134317734 ODU link broken 2 59 2 2 46 134317743 SNCP channel changeover Interruption 2 59 2 3 Handling Alarm 2 60 2 3 1 134218745 Ins...

Страница 6: ...attery dry contact alarm 2 76 2 4 15 403 PP voltage abnormal 2 77 2 4 16 404 MP overcurrented 2 77 2 4 17 405 PP overcurrented 2 78 2 4 18 406 Fan failure 2 79 2 5 QoS Alarm 2 80 2 5 1 134243772 EFM local link event 2 80 2 5 2 134243778 EFM loopback alarm 2 80 Chapter 3 Notification 3 1 3 1 10001 Board power on completed 3 2 3 2 10002 Standby board power on completed 3 2 3 3 10003 PM active to sta...

Страница 7: ... does not include the router 3 15 3 25 134243745 Timeout for receiving OSPF hello packet 3 16 3 26 134243746 OSPF interface disabled by administrator 3 16 3 27 134243747 OSPF interface disabled physically 3 17 3 28 134243748 interface s neighbor changed 3 17 3 29 134243763 The port failing to be aggregated into a LAG 3 18 3 30 134243764 The port quitting a LAG due to exception 3 19 3 31 134243773 ...

Страница 8: ...VI ...

Страница 9: ...t Is in This Manual This manual has the following chapters Chapter Description 1 Overview Gives an overview of NR8250 alarms and notifications 2 Alarms Describes the alarms in terms of alarm properties probable causes effect on the system and handling procedure 3 Notifications Describes the notifications in terms of notification properties probable causes effect on the system and handling procedur...

Страница 10: ...II ...

Страница 11: ...dication The fault management system indicates a fault or event occurring in the network in the form of alarm or notification 1 2 1 Alarm A fault is indicated in the form of alarm when it persists and affects the reliability and services of the system An alarm will be cleared only after the fault is resolved Immediate troubleshooting is required when alarms occur 1 2 2 Notification A notification ...

Страница 12: ...luences proper system operations or reduces service capabilities Proper measures should be taken to clear the fault in a timely manner and prevent the occurrence of more severe alarms when a major alarm occurs l Warning A warning indicates a fault that has a potential or gradual impact on proper system operations or service capabilities Warning messages need to be analyzed and proper measures shou...

Страница 13: ...ach alarm and the impact on the system and services are provided 1 3 4 Handling Procedure Troubleshooting steps and suggestions are provided During the alarm handling process the following tips needs your attention l After recording the fault information O M personnel needs to handle the fault step by step as suggested If there is no otherwise specified and the fault is solved that is alarm is cle...

Страница 14: ... the system and services are provided 1 4 4 Handling Procedure Troubleshooting steps and suggestions are provided During the alarm handling process the following tips needs your attention l After recording the fault information O M personnel needs to handle the fault step by step as suggested If there is no otherwise specified and the fault is solved that is alarm is cleared the alarm handling pro...

Страница 15: ...e 1 Management power l Sub code 2 Service power Effect on the System The board s communication link is broken and services carried by the board are interrupted Possible Causes The board is powered off Handling Procedure 1 Check the additional information of the alarm If the alarm has additional information check whether the inserted board of the NE is inconsistent with that configured at OMCB The ...

Страница 16: ...cal Maintenance Terminal LMT but not actually inserted in that slot 2 The board is configured in a slot on the LMT but not tightly inserted in that slot 3 The board is configured in a slot on the LMT but the connecting part is physically damaged Handling Procedure 1 Check whether the board is inserted into the slot l If yes go to step 2 l If no insert the board 2 Pull out and plug the board into t...

Страница 17: ...f no pull out the board 2 1 4 134217728 Clock reference source lost Alarm Property l Alarm Code 134217728 l Alarm Information The alarm is reported if the RCU cannot detect the clock signal of configured clock reference source l Alarm Level Minor l Alarm Type Equipment Alarm Sub code Description l Sub code 1 RCU 1PPS TOD clock lost l Sub code 2 RCU BITS clock lost l Sub code 4 Slot3 clock lost l S...

Страница 18: ...s replace the faulty RTU board 3 For the air interface clock reference ensure that the radio link is locked that is the LINK indicator on the RMUB board is lit If the alarm persists replace the faulty RMU board 4 For the SyncE or 1588 clock ensure that the GbE ports on RCUB RTUN RTUH board are connected with proper cables If the alarm persists replace the faulty RCUB RTUN RTUH board 2 1 5 13421772...

Страница 19: ...e SNTP server 4 If the alarm persists after the preceding steps replace the faulty RCU board 2 1 6 134217730 RTC clock alarm Alarm Property l Alarm Code 134217730 l Alarm Information The alarm is reported if the master RTC clock timing fails l Alarm Level Minor l Alarm Type Equipment Alarm Sub code Description l Sub code 1 RTC clock failure l Sub code 2 RTC clock not set Effect on the System The s...

Страница 20: ...iorated Effect on the System If the active main control board is faulty the system cannot operate properly which causes all bearing services to interrupt Possible Causes 1 The system clock reference source is lost 2 The system clock reference source is degraded 3 The local clock is faulty Handling Procedure 1 Check whether the clock reference source has the associated alarm 134217728 Clock Referen...

Страница 21: ...Alarm Property l Alarm Code 134218747 l Alarm Information This alarm is reported if no power is supplied to PS port of RPUA or the power supply is abnormal l Alarm Level Minor l Alarm Type Equipment Alarm Sub code Description l Sub code 1 RPUA PS1 powered off l Sub code 2 RPUA PS2 powered off Effect on the System If RPUA PS1 and RPUA PS2 are powered off simultaneously the ODU will be powered off a...

Страница 22: ...des in the signal received by the board exceeds the threshold This alarm may affect the signal service quality Possible Causes l The alarm may be generated together with other high level alarms l The fiber connector is not clean or the optical module is not matched l The signal source of the upstream equipment is faulty l The NR8250 equipment fails to receive upstream service signals Handling Proc...

Страница 23: ... LMT displays E1 8 l 134807552 E1 9 port LMT displays E1 9 l 134873088 E1 10 port LMT displays E1 10 l 134938624 E1 11 port LMT displays E1 11 l 135004160 E1 12 port LMT displays E1 12 l 135069696 E1 13 port LMT displays E1 13 l 135135232 E1 14 port LMT displays E1 14 l 135200768 E1 15 port LMT displays E1 15 l 135266304 E1 16 port LMT displays E1 16 l 135331840 E1 16 port LMT displays E1 17 l 135...

Страница 24: ...s STM4 and LMT displays STM4 Channel 4 Effect on the System Traffic is interrupted when the wireless link port is in loopback status Possible Causes 1 The loopback function is enabled for testing or maintenance 2 The board that reports the alarm is faulty Handling Procedure 1 Check whether loopback is configured for test or maintenance l If yes after the maintenance or test is completed disable th...

Страница 25: ...ion l Sub code 1 Optical port 1 on the RTUB board l Sub code 2 Optical port 2 on the RTUB board Effect on the System The optical module not in position may cause the service via the port to interrupt Possible Causes 1 Optical module is not inserted 2 Optical module is faulty Handling Procedure Check whether the optical module is inserted l If yes replace the optical module l If no insert the optic...

Страница 26: ...er and enable the optical module and the alarm is cleared l If no go to step 2 2 Replace the RTU board where the optical module is inserted 2 1 15 134239932 ODU configuration mode invalid Alarm Property l Alarm Code 134239932 l Alarm Information The alarm is reported if ODU does not support the issued configuration mode l Alarm Level Critical l Alarm Type Equipment Alarm Sub code Description None ...

Страница 27: ...System The system is working in the co frequency dual polarization mode If XPIC is abnormal the radio link receive performance becomes abnormal and the problems of error code or disconnection occur Possible Causes l The XPIC function requires both normal RMUC boards to enable the XPIC function The boards are not configured as required or the XPIC function is not enabled l In a pair of RMUCs each o...

Страница 28: ...d with the XPIC function use the same ODU frequency Ensure that the two RMUC boards of an XPIC group use the same bandwidth 2 1 17 134239937 ODU power supply abnormal Alarm Property l Alarm Code 134239937 l Alarm Information The alarm is reported when the 48V power supply of ODU is abnormal or lost l Alarm Level Critical l Alarm Type Equipment Alarm Sub code Description None Effect on the System I...

Страница 29: ...ort is in loopback status Possible Causes 1 The loopback function is enabled for test or maintenance 2 The board that reports the alarm is faulty Handling Procedure 1 Select Maintenance Port Loopback ETH and check whether loopback is configured for test or maintenance l If yes disable the loopback function after the test or maintenance is completed l If no replace the faulty board 2 If the alarm p...

Страница 30: ...as the destination address and VLAN information 3 Check the network connections between the slave device and the master device 2 1 20 134243766 1588 clock PTP link abnormal Alarm Property l Alarm Code 134243766 l Alarm Information The alarm is reported if a PTP link has serious packet loss problem l Alarm Level Minor l Alarm Type Equipment Alarm Sub code Description None Effect on the System The 1...

Страница 31: ...reference clock source through the clock protection function Possible Causes l The threshold configuration is unreasonable l Network problems occur for example the cable is faulty Handling Procedure Check the network connection of all PTP links 1 Select Clock PTP Global Configuration and check whether the packet loss rate threshold is reasonable in case of Ordinary Clock 2 Ensure that the network ...

Страница 32: ...perates properly 2 1 23 134317741 Loopback state in IF or modem port Alarm Property l Alarm Code 134317741 l Alarm Information The alarm is reported if loopback is performed at the radio link port that is when the port on MU is in the loopback status IF modulation and demodulation l Alarm Level Major l Alarm Type Equipment Alarm Sub code Description l Sub code 2 Setting modulation and demodulation...

Страница 33: ...tion None Effect on the System The services using this route are interrupted Possible Causes The system fails to configure the SNCP route Handling Procedure Invalidate the route again 2 1 25 9001 AC input Switch Off Alarm Property l Alarm Code 9001 l Alarm Information AC input switch is off l Alarm Level Critical l Alarm Type Equipment Alarm Sub code Description None Effect on the System 1 The rec...

Страница 34: ...ndby AC input l Alarm Level Critical l Alarm Type Equipment Alarm Sub code Description None Effect on the System 1 The rectifier fails to work normally only the battery can work 2 The system does not implement battery management 3 When the battery runs out the base station is powered down Possible Causes 1 The AC power supply is powered down 2 The AC transducer s connection is faulty or the transd...

Страница 35: ...s socket is of bad contact or disconnected 6 The monitoring unit is faulty Handling Procedure 1 The lightning protector is damaged Replace the lightning protector 2 Check whether the lightning protector s air break switch is closed 3 Check whether the lightning protector s base is of bad contact 4 Check whether the contact of the lightning protector s base is disconnected or of bad contact 5 Check...

Страница 36: ... the contact of the lightnring unit is faulty 5 Check the monitoring unit s connection 6 Replace the monitoring unit 2 1 29 9005 AC Under Volt Alarm Property l Alarm Code 9005 l Alarm Information The AC input phase voltage is lower than Phase OverVolt l Alarm Level Minor l Alarm Type Equipment Alarm Sub code Description None Effect on the System The load capacity of the power supply is influenced ...

Страница 37: ...ion safety of the rectifier is influenced 2 The rectifier will automatically power off for protection Possible Causes 1 The AC input voltage is high 2 The AC over voltage value of the monitoring unit is set too low 3 The AC transducer s connection is faulty or the transducer is damaged 4 The monitoring unit s socket is of bad contact or disconnected 5 The monitoring unit is faulty Handling Procedu...

Страница 38: ...hold value for the alarm 2 The power supply s load is too heavy 3 The monitoring unit s socket is of bad contact or disconnected 4 The monitoring unit is faulty Handling Procedure 1 Check the threshold value of the monitoring unit s AC input current 2 Check whether the AC input voltage is too low 3 Check whether the AC power supply is overloaded 4 Check whether the monitoring unit s socket is inse...

Страница 39: ...djust the link attenuation and the transmit power of the ODU at the remote end 2 2 2 134217736 UAS alarm at air interface Alarm Property l Alarm Code 134217736 l Alarm Information This alarm is reported when UAS change at the air interface is detected l Alarm Level Major l Alarm Type Communications Alarm Sub code Description None Effect on the System This alarm affects traffic Possible Causes The ...

Страница 40: ...e UAS to occur Handling Procedure 1 Check whether the receive power and transmit power of the optical module are normal l If yes go to step 2 l If no replace the optical module and ensure that the uplink equipment operates properly 2 Replace the RTUB 2 2 4 134217738 UAS alarm of RS Alarm Property l Alarm Code 134217738 l Alarm Information This alarm is reported when UAS change at RS is detected l ...

Страница 41: ...BER less than 10 3 l Alarm Level Critical l Alarm Type Communications Alarm Sub code Description l Sub code 1 Optical port 1 on the RTUB board l Sub code 2 Optical port 2 on the RTUB board Effect on the System Signals carried by fiber are interrupted This may interrupt the traffic of the optical port Possible Causes The optical does not have input signal Handling Procedure 1 Select TDM Laser enabl...

Страница 42: ...t 10 on the panel l Sub code 11 E1 port 11 on the panel l Sub code 12 E1 port 12 on the panel l Sub code 13 E1 port 13 on the panel l Sub code 14 E1 port 14 on the panel l Sub code 15 E1 port 15 on the panel l Sub code 16 E1 port 16 on the panel l Sub code 17 E1 port 17 on the panel l Sub code 18 E1 port 18 on the panel l Sub code 19 E1 port 19 on the panel l Sub code 20 E1 port 20 on the panel l ...

Страница 43: ... Replace the RTU board 2 2 7 134237733 RS LOF Alarm Property l Alarm Code 134237733 l Alarm Information The alarm indicates that interruption occurs at the regenerator section The local end does not receive the signal from the remote end l Alarm Level Critical l Alarm Type Communications Alarm Sub code Description l Sub code 1 Optical port 1 on the RTUB board l Sub code 2 Optical port 2 on the RTU...

Страница 44: ... section The local end does not receive the signal from the remote end l Alarm Level Critical l Alarm Type Communications Alarm Sub code Description l Sub code 1 Optical port 1 on the RTUB board l Sub code 2 Optical port 2 on the RTUB board Effect on the System The board cannot identify the data frame for the received SDH signal and the service is interrupted Possible Causes 1 The clock configurat...

Страница 45: ...affect the signal service quality Possible Causes l The alarm may be generated together with other high level alarms l The fiber connector is not clean or the optical module is not matched l The signal source of the upstream equipment is faulty l The NR8250 equipment fails to receive upstream service signals Handling Procedure 1 Check whether alarms with higher severity levels are generated l If y...

Страница 46: ...eam equipment to NR8250 equipment contains the MS RDI information 3 The RTUB board that reports the alarm is faulty Handling Procedure 1 Check whether NR8250 uplink equipment reports alarms such as RS LOS RS LOF or MS EXC l If yes handle the alarm by referring to the corresponding handling suggestion l If no go to step 2 2 Ensure that the signals sent by upstream equipment to NR8250 equipment do n...

Страница 47: ...alarms such as TU AIS l If yes handle the alarm by referring to the TU AIS alarm of the NR8250 equipment l If no go to step 2 2 Ensure that the signals sent by upstream equipment to NR8250 equipment do not contain the TU RDI signal 3 The alarm is caused by RTUB board failure Replace the board 2 2 12 134237745 MS AIS Alarm Property l Alarm Code 134237745 l Alarm Information MS Alarm Indication Sign...

Страница 48: ... AIS l Alarm Level Major l Alarm Type Communications Alarm Sub code Description Each subcode represents a timeslot The former 63 timeslots are used for optical port 1 and the latter 63 timeslots are used for optical port 2 Effect on the System The receive signal transmitted on the SDH link is interrupted Possible Causes 1 The signals sent from the upstream equipment to NR8250 equipment contains th...

Страница 49: ...e system service is not affected Possible Causes 1 Invalid H4 bytes are detected at the upstream direction 2 The RTUB board that reports the alarm fails Handling Procedure None 2 2 15 134237748 HP UNEQ Alarm Property l Alarm Code 134237748 l Alarm Information The alarm is reported if higher order path is not equipped and C2 in more than five consecutive frames is 00H l Alarm Level Major l Alarm Ty...

Страница 50: ...failure Replace the board 2 2 16 134237749 TU UNEQ Alarm Property l Alarm Code 134237749 l Alarm Information The alarm is reported if tributary unit is not equipped l Alarm Level Major l Alarm Type Communications Alarm Sub code Description Each subcode represents a timeslot The former 63 timeslots are used for optical port 1 and the latter 63 timeslots are used for optical port 2 Effect on the Sys...

Страница 51: ...LMT displays 2STM 1 Effect on the System The carried services are affected Possible Causes 1 The J1 byte received by the NR8250 is inconsistent with that sent by the upstream equipment 2 The RTUB board that reports the alarm is faulty Handling Procedure 1 Check whether the transmission value of VC 4 path access point identifier J1 byte of the upstream equipment and the J1 expectation value of the ...

Страница 52: ...d This is detected by C2 l Alarm Level Major l Alarm Type Communications Alarm Sub code Description l Sub code 1 STM 1 of optical port 1 LMT displays STM 1 l Sub code 5 Path 1 of optical port 2 LMT displays STM 4 Channel1 l Sub code 6 Path 2 of optical port 2 LMT displays STM 4 Channel2 l Sub code 7 Path 3 of optical port 2 LMT displays STM 4 Channel3 l Sub code 8 Path 4 of optical port 2 LMT disp...

Страница 53: ... represents a timeslot The former 63 timeslots are used for optical port 1 and the latter 63 timeslots are used for optical port 2 Effect on the System All the relay receive signals transmitted on the SDH link may be interrupted Possible Causes 1 The signal flag received by NR8250 equipment is inconsistent with that sent by the upstream equipment 2 The RTUB board that reports the alarm is faulty H...

Страница 54: ... clock again 3 The alarm is caused by RTUB board failure Replace the board s 2 2 22 134237928 HP RDI Alarm Property l Alarm Code 134237928 l Alarm Information The local end detects the HP TIM or HP SLM signal l Alarm Level Major l Alarm Type Communications Alarm Sub code Description l Sub code 1 STM 1 of optical port 1 LMT displays STM 1 l Sub code 5 Path 1 of optical port 2 LMT displays STM 4 Cha...

Страница 55: ...Sub code Description l Sub code 1 STM 1 of optical port 1 LMT displays STM 1 l Sub code 5 Path 1 of optical port 2 LMT displays STM 4 Channel1 l Sub code 6 Path 2 of optical port 2 LMT displays STM 4 Channel2 l Sub code 7 Path 3 of optical port 2 LMT displays STM 4 Channel3 l Sub code 8 Path 4 of optical port 2 LMT displays STM 4 Channel4 l Sub code 10 STM 1 of optical port 2 LMT displays 2STM 1 E...

Страница 56: ...ode 8 Path 4 of optical port 2 LMT displays STM 4 Channel4 l Sub code 10 STM 1 of optical port 2 LMT displays 2STM 1 Effect on the System All the relay receive signals transmitted on the SDH link may be interrupted Possible Causes 1 The signals sent from the upstream equipment to NR8250 equipment contains the AU LOP signal 2 The RTUB board that reports the alarm is faulty Handling Procedure 1 Ensu...

Страница 57: ...p 2 l If no modify the trace identification of VC 4 channel J0 ZTE MW NR8250 2 The alarm is caused by RTUB board failure Replace the board 2 2 26 134237934 E1 AIS Alarm Property l Alarm Code 134237934 l Alarm Information The alarm indicates that every bit of the digital signal is 1 The alarm is reported if at least 255 consecutive bits in the received signal is 1 l Alarm Level Critical l Alarm Typ...

Страница 58: ...e 26 E1 port 26 on the panel l Sub code 27 E1 port 27 on the panel l Sub code 28 E1 port 28 on the panel l Sub code 29 E1 port 29 on the panel l Sub code 30 E1 port 30 on the panel l Sub code 31 E1 port 31 on the panel l Sub code 32 E1 port 32 on the panel Effect on the System The E1 receive relay signal carried by the TU is interrupted Possible Causes 1 The upstream E1 signal sent to NR8250 equip...

Страница 59: ...eceiving level 3 Check if interference exists If yes find out the frequency of the interference source and change the device frequency 4 Adjust the antenna height l For long time unlocking 1 Check whether the ODU frequencies at both ends match each other 2 Check whether the configurations of bandwidth and modulation mode are consistent at both ends 3 Check whether the IF output interface of the OD...

Страница 60: ...ion function that RMU is configured with does not take effect thus the protection cannot be implemented Possible Causes 1 The configurations at both ends are incorrect 2 The local transceiver and the remote transceiver are faulty 3 The NR8250 shelf at the local end is faulty Handling Procedure 1 Check whether the configurations at the two ends including ODU frequency modulation modes and bandwidth...

Страница 61: ...ive and standby traffic units in non protection mode it leads to traffic interruption l Sub code 1 In protection mode it leads to switchover between active and standby traffic units in non protection mode it leads to traffic interruption l Sub code 2 In protection mode it leads to switchover between active and standby traffic units in non protection mode it leads to traffic interruption l Sub code...

Страница 62: ...Power off and then restart the ODU If the alarm persists replace the ODU l Sub code 2 Power off and then restart the ODU If the alarm persists replace the ODU l Sub code 3 Power off and then restart the ODU If the alarm persists replace the ODU l Sub code 4 Replace the ODU l Sub code 5 Power off and then restart the ODU If the alarm persists use a shorter IF cable l Sub code 6 Ensure that the ODU ...

Страница 63: ...sion unit failure 1 1 caused by the ODU alarm Tx RF PLL loss of lock Tx IF PLL loss of lock Rx RF PLL loss of lock Rx IF PLL loss of lock l Sub code 3 Transmission unit failure 1 0 caused by the ODU alarm Tx RF PLL loss of lock Tx IF PLL loss of lock Rx RF PLL loss of lock Rx IF PLL loss of lock Effect on the System The traffic carried by the transmission unit is interrupted Possible Causes Refer ...

Страница 64: ...sed users manually set the transmission power of two ODUs to 0 by selecting ODU Mute Enable b If HSB and SD are used users manually set the transmission power of the active ODU to 0 by selecting Mute Enable Handling Procedure Do not select Mute Enable 2 2 32 134241729 Ethernet port disconnected Alarm Property l Alarm Code 134241729 l Alarm Information The alarm is reported when the Ethernet port i...

Страница 65: ...jor l Alarm Type Communications Alarm Sub code Description None Effect on the System It does not affect the traffic carried by the board The purpose is to inform the administrator that the link may be blocked Possible Causes 1 No MEP is configured at the opposite end NE 2 The bearer layer is faulty 3 The network is seriously congested Handling Procedure 1 Check whether the MEP is correctly configu...

Страница 66: ...or that the basic CFM configuration has errors Possible Causes RMEP is faulty or RMEP configuration is incorrect Handling Procedure Check whether each RMEP configuration IP address MAC address an CCM packet sending period of MD MA LMEP and LMEP corresponding to the LMEP in the alarm is consistent with the LMEP configuration of corresponding MA at the remote end If no modify the configurations to b...

Страница 67: ...ystem It does not affect the traffic carried by the board It indicates that a section or node of the link covered in maintenance association MA is faulty and some traffic stream will be interrupted Possible Causes Some MEPs in the same MA has alarms Handling Procedure Check the MEP in alarm in the MA for the alarm type Remove the fault according to the alarm type 2 2 37 134243755 Ethernet devices ...

Страница 68: ...e link If yes correct it 2 2 38 134243756 Frame loss rate exceeding the threshold Alarm Property l Alarm Code 134243756 l Alarm Information The alarm is reported if the proportion between the number of lost data packets and the number of sent data packets exceeds the threshold l Alarm Level Major l Alarm Type Communications Alarm Sub code Description None Effect on the System It does not affect th...

Страница 69: ...ted or there are too many NEs on the traffic path Handling Procedure Check the bandwidth usage and check the Nes on the link 2 2 40 134243758 Link delay jitter exceeding the threshold Alarm Property l Alarm Code 134243758 l Alarm Information The alarm is reported if the link delay is unstable with too much jitter l Alarm Level Major l Alarm Type Communications Alarm Sub code Description None Effec...

Страница 70: ...the local link is faulty the service at the port may be disconnected Possible Causes The local end detects link fault Handling Procedure Check the LMT or panel status for the physical connections of the local optical port Troubleshoot the ports 2 2 42 134243770 EFM remote link fault Alarm Property l Alarm Code 134243770 l Alarm Information The alarm is reported if the local end detects the link fa...

Страница 71: ...Sub code 3 The remote OAM does not satisfy the requirement of the local OAM 4 Sub code 4 The local OAM does not satisfy the requirement of the remote OAM Effect on the System The service at the port may be disconnected Possible Causes The discovery process fails Handling Procedure 1 On the Local Maintenance Terminal LMT check whether there are alarms related to the optical module or boards l If ye...

Страница 72: ...at the local end and the remote end of EFM Handling Procedure 1 On the LMT check whether there are alarms related to the optical module or boards l If yes remove the faults of the optical module and board l If no go to step 2 2 On the LMT check whether the optical fibers or cables are faulty l If yes replace the faulty fiber or cable l If no go to step 3 3 On the LMT check the OAM parameter settin...

Страница 73: ...powered on 2 The RMU board of IDU is faulty 3 The ODU is faulty Handling Procedure 1 Check whether the power supply to the ODU is normal 40 V 60 V l If yes go to step 2 l If no remove the fault 2 Check whether the IF cable is in good condition and the IF cable connectors are made properly l If yes go to step 3 l If no remove the IF faults 3 Replace the RMU board If the alarm persists replace the O...

Страница 74: ...sh memory Alarm Property l Alarm Code 134218745 l Alarm Information This alarm is reported when flash memory does not have sufficient space l Alarm Level Major l Alarm Type Handling Alarm Sub code Description None Effect on the System This alarm does not affect any traffic but it may cause data saving failure Possible Causes The flash memory is insufficient Handling Procedure In Version Management...

Страница 75: ...ce configurations include version number area configuration network mask Hello timer interval and Dead timer interval Handling Procedure Ensure that the interface configurations at the two ends match 2 3 3 134243739 OSPF virtual link interface configuration error Alarm Property l Alarm Code 134243739 l Alarm Information The alarm is reported if the OSPF virtual interface configuration is incorrect...

Страница 76: ...rd and master main control board is interrupt l Alarm Level Critical l Alarm Type Handling Alarm Sub code Description None Effect on the System The board fails to communicate with the active main control board causing that the services carried by the board are interrupted Possible Causes 1 The board is configured in the network management system but it is not inserted in the rack 2 The link betwee...

Страница 77: ... select Maintenance Version IDU and check whether the software version is correct l If no download the correct version package l If yes go to step 2 2 Replace the board 2 3 6 6203 Software version synchronization failure between active board and standby board Alarm Property l Alarm Code 6203 l Alarm Information When the standby main control board fails to synchronize the software version with that...

Страница 78: ...bility is affected that is the active standby changeover is disabled l Case 2 After active standby changeover occurs the boards related to the software cannot operate properly and the services carried by the board are interrupted Possible Causes The standby board fails to synchronize files with those in relevant directories at the active board Handling Procedure 1 In the software version managemen...

Страница 79: ... to step 2 2 Replace the board 2 3 8 6206 Running software version fault Alarm Property l Alarm Code 6206 l Alarm Information When the main control board detects that the running software version does not exist this alarm is reported l Alarm Level Major l Alarm Type Handling Alarm Sub code Description l 3145728 RCUA CPU version l 3147776 RCUA FPGA version l 9503265 RTUA CPU version or RTUB CPU ver...

Страница 80: ...rm Information If the active main control board fails to synchroize its software version with that of the standby main control board the alarm is reported l Alarm Level Major l Alarm Type Handling Alarm Sub code Description l Sub code 0 CPU software l Sub code 1 FPGA software Effect on the System The active standby changeover cannot be implemented Possible Causes 1 The software version of the main...

Страница 81: ...configuration at NetWork Management is incorrect or the board is incorrectly inserted Handling Procedure 1 On the LMT select Setup Shelf and check whether the board configuration is correct l If yes go to step 2 l If no correct the configuration 2 Replace the incorrect boards 2 3 11 6214 Software version abnormal Alarm Property l Alarm Code 6214 l Alarm Information If the software version consiste...

Страница 82: ... s running patch is abnormal the services will be affected after the board is reset How much the services are affected depends on the service importance l If it is other software package that is abnormal the service will not be affected Possible Causes If the software version consistency check indicates that the version in software package does not exist on the disk or is damaged this alarm is rep...

Страница 83: ...ironment Alarm Sub code Description None Effect on the System The port is blocked for some time Possible Causes The port configured with LOOP Guard function does not receive the BPDU packet for a long time Handling Procedure Check whether the port should be configured with LOOP Guard function whether the link is congested whether there are unidirectional link problems and whether the port receives...

Страница 84: ...n such as bridge priority is correct 1 Check whether the bridge whether the port is located is a root bridge l If yes go to step 2 l If no delete the ROOT protection configuration of the port 2 Check whether the expected root bridge does not actually serve as the root due to incorrect network bridge configuration for example incorrect network bridge priority l If yes modify the configuration l If ...

Страница 85: ...set the fans to a high shift position l If the alarm persists check whether the fans fail to work If yes replace the fans 3 If the alarm persists after the preceding steps it indicates that the board in the corresponding slot is faulty Replace the board 2 4 5 4001 Outdoor temperature alarm Alarm Property l Alarm Code 4001 l Alarm Information The temperature of the outdoor monitoring device is abno...

Страница 86: ... upper threshold it is over voltage l When the input voltage of PM board is lower than the lower threshold it is under voltage Handling Procedure Over voltage Use a multimeter or other tools to check whether the input DC voltage is higher than or equal to 56 V If yes replace the DC power supply system If not replace the PM board Under voltage Use a multimeter or other tools to check whether the in...

Страница 87: ...is abnormal l Alarm Level Major l Alarm Type Environment Alarm Sub code Description Moisture alarm dry contact Effect on the System The outdoor monitoring device is abnormal It does not affect the system performance Possible Causes The moisture condition of the outdoor monitoring device is abnormal Handling Procedure None 2 4 9 4013 Outdoor smoke alarm Alarm Property l Alarm Code 4013 l Alarm Info...

Страница 88: ...ng device is abnormal is abnormal l Alarm Level Major l Alarm Type Environment Alarm Sub code Description l Sub code 1 Lightning protection dry contact 1 is abnormal l Sub code 2 Lightning protection dry contact 2 is abnormal Effect on the System The outdoor monitoring device is abnormal It does not affect the system performance Possible Causes The lightning protection module of the outdoor monito...

Страница 89: ...door fan dry contact alarm Alarm Property l Alarm Code 4018 l Alarm Information fan is in fault l Alarm Level Major l Alarm Type Environment Alarm Sub code Description None Effect on the System outdoor machine cabinet is abnormal and it does not affect the system Possible Causes The fan of outdoor machine cabinet is abnormal Handling Procedure 1 Check whether the fan box has been installed 2 Check...

Страница 90: ...ceeds the upper threshold it is over voltage and the voltage will be restored when the voltage is lower than the upper threshold l When the MP voltage reported by the PM board is lower than the lower threshold it is under voltage and the voltage will be restored when the voltage exceeds the lower threshold Handling Procedure Replace the PM board 2 4 14 4020 outdoor battery dry contact alarm Alarm ...

Страница 91: ...ted and the board cannot bear any service Possible Causes l When the PP voltage reported by the PM board exceeds the upper threshold it is over voltage and the voltage will be restored when the voltage is lower than the upper threshold l When the PP voltage reported by the PM board is lower than the lower threshold it is under voltage and the voltage will be restored when the voltage exceeds the l...

Страница 92: ...place the corresponding board 3 Replace PM board 4 Replace the backplane 2 4 17 405 PP overcurrented Alarm Property l Alarm Code 405 l Alarm Information This alarm is reported when the PP current is out of range and cleared when the current becomes normal l Alarm Level Minor l Alarm Type Environment Alarm Sub code Description None Effect on the System The power to the over current board is turned ...

Страница 93: ...lure l Sub code 5 Fan 5 Failure l Sub code 6 Fan 6 Failure Effect on the System This alarm may cause the equipment overtemperature alarm and causes boards or the system to operate improperly the system performance to degrade and services to interrupt Possible Causes The fan fails Handling Procedure Replace the fan If the alarm persists the shelf may be faulty because the power supply to the fan is...

Страница 94: ...of errored symbols of the physical layer within the unit time exceeds the preset threshold 2 The number of errored frames of the MAC layer within the unit time exceeds the preset threshold 3 The number of errored frames of MAC layer within the unit frame amount exceeds the preset threshold 4 The number of errored frame seconds of the MAC layer within the unit time exceeds the preset threshold Hand...

Страница 95: ...cedure 1 Ensure that the remote loopback response parameter of the port that reports the alarm is disabled 2 Check the ETH_EFM_LOOPBACK alarm of the remote NE and find out the port that initiates loopback towards the remote NE This alarm does not indicates a fault If the port is not expected to be involved in the loopback test to avoid traffic flow interruption do as follows 1 Set the remote loopb...

Страница 96: ...ZXMW NR8250 Alarm and Notification Handling Reference This page intentionally left blank 2 82 SJ 20111008094748 008 2012 05 30 R1 1 ZTE Proprietary and Confidential ...

Страница 97: ...d 3 12 134243740 OSPF interface receiving incorrect packet 3 13 134243741 OSPF virtual link interface receiving incorrect packet 3 13 134243742 OSPF interface receiving incorrect LSR packet 3 14 134243743 OSPF interface receiving incorrect DD packet sequence number 3 15 134243744 Hello packet received at OSPF interface does not include the router 3 15 134243745 Timeout for receiving OSPF hello pac...

Страница 98: ...larm Sub code Description None Effect on the System None Possible Causes The board is powered on Handling Procedure None 3 2 10002 Standby board power on completed Notification Property l Notification Code 10002 l Notification Information The notification is reported to indicate that the standby board is in working status and active standby switchover can be performed l Notification Type Equipment...

Страница 99: ...Possible Causes It is the notification of the active to standby changeover being completed Handling Procedure None 3 4 10004 PM standby to changeover completed Notification Property l Notification Code 10004 l Notification Information The notification is reported to indicate that the standby PM board serves as the active board and the active PM board serves as the standby board l Notification Type...

Страница 100: ...Type Equipment Alarm Sub code Description l Sub code 1 Process power on failure l Sub code 2 Process power on timeout Effect on the System The board fails to operate normally Possible Causes The process fails to be powered on or timeout Handling Procedure Check whether module timeout occurs If yes change the software version 3 6 10012 Module reset Notification Property l Notification Code 10012 l ...

Страница 101: ...on Type Equipment Alarm Sub code Description l Sub code 1 The module is powered down l Sub code 2 General module fault Effect on the System The module status is abnormal Possible Causes The module s status is abnormal Handling Procedure Extract and insert the board 3 8 10014 Changeover completed Notification Property l Notification Code 10014 l Notification Information The active standby RCUB boar...

Страница 102: ...eted Handling Procedure None 3 9 10015 Changeover failure Notification Property l Notification Code 10015 l Notification Information The active standby RCUB board changeover fails l Notification Type Handling Alarm Sub code Description l Sub code 1 Initiate switchover in LMT l Sub code 2 Press button for switchover l Sub code 3 Reset the main board in LMT l Sub code 4 Partner machine the active bo...

Страница 103: ...board is abnormal l Sub code 6 The interval between two consecutive changeover is less than 5 minutes l Sub code 7 The network interface status of the standby board is abnormal l Sub code 8 The version management process forbids changeover l Sub code 9 The entire table configuration forbids changeover Effect on the System The active standby status of the main control board cannot be modified Possi...

Страница 104: ... packet Possible Causes Change the configuration of LLDP global enable Handling Procedure No processing is required 3 12 134243729 Local management address of LLDP changed Notification Property l Notification Code 134243729 l Notification Information The alarm is reported when the local management address is changed l Notification Type Communications Alarm Sub code Description None Effect on the S...

Страница 105: ...e Causes 1 The ports receives the packet of a new neighbor 2 The port receives the shutdown packet from the neighbor and deletes the information 3 The port receives the neighbor information change packet 4 The number of port neighbors exceeds the maximum limit 8 and no neighbor can be added 5 The port cannot receive LLDP packets from a neighbor for a long time and the neighbor information is aging...

Страница 106: ...34243732 8032 port unblocked Alarm Property l Alarm Code 134243732 l Alarm Information The notification is reported if the 8032 protocol sends a unblock request to the switching chip and the chip is unblocked l Alarm Type Equipment Alarm Sub code Description l Sub code 1 The port is unblocked due to local link recovery l Sub code 2 The RPL OWNER port is unblocked due to the SF packet being receive...

Страница 107: ...back Down Waiting PTP Backup DROther and DR Handling Procedure No processing is required 3 17 134243734 OSPF virtual interface status changed Notification Property l Notification Code 134243734 l Notification Information The alarm is reported if the OSPF virtual interface status is changed l Notification Type Handling Alarm Sub code Description None Effect on the System None Possible Causes The OS...

Страница 108: ...Possible Causes The status of an OSPF interface neighbor is changed All OSPF interface neighbor status packets include Down Init 2Way ExStart Exchange Load and Full Handling Procedure No processing is required 3 19 134243736 OSPF virtual neighbor status changed Notification Property l Notification Code 134243736 l Notification Information The alarm is reported if the OSPF virtual interface neighbo...

Страница 109: ...cket which cannot be parsed l Notification Type Handling Alarm Sub code Description None Effect on the System This alarm may cause LSDB synchronization failure Possible Causes The contents of the DD LSR LSAck and LSU packets are incorrect Handling Procedure No processing is required 3 21 134243741 OSPF virtual link interface receiving incorrect packet Notification Property l Notification Code 1342...

Страница 110: ...rrect LSR packet Notification Property l Notification Code 134243742 l Notification Information The alarm is reported if OSPF interface receives incorrect LSR packet from the neighbor l Notification Type Handling Alarm Sub code Description None Effect on the System This alarm may cause LSDB resynchronization Possible Causes The requested LSA does not exist or the interface does not support the req...

Страница 111: ...otiation flag or the sequence number is incorrect during DD exchange Handling Procedure No processing is required 3 24 134243744 Hello packet received at OSPF interface does not include the router Notification Property l Notification Code 134243744 l Notification Information The alarm is reported when the Hello packet received at the interface where OSPF is implemented does not include this router...

Страница 112: ...ling Alarm Sub code Description None Effect on the System The interface to the neighbor is disabled Possible Causes l The neighbor does not exist l The link is interrupted l The neighbor OSPF interface is down Handling Procedure Check the neighbor status 3 26 134243746 OSPF interface disabled by administrator Notification Property l Notification Code 134243746 l Notification Information The notifi...

Страница 113: ... interface is disabled due to physical reasons such as network media l Notification Type Handling Alarm Sub code Description None Effect on the System The neighbor status is changed and the route may be recalculated Possible Causes The network media is disconnected Handling Procedure Check the pyhsical connections 3 28 134243748 interface s neighbor changed Alarm Property l Alarm Code 134243748 l ...

Страница 114: ...ort fails to be aggregated into a LAG l Notification Type Handling Alarm Sub code Description None Effect on the System The port is blocked for some time Possible Causes l The duplex mode of the LAG member ports is set to half duplex l The status of the LAG member ports is PhyDown or Admin Down Handling Procedure 1 Check the property configuration of the LAG ports Ensure that the duplex mode is fu...

Страница 115: ...ck the property configuration of the LAG member ports Ensure that the port configurations are consistent for the two aggregation member devices 2 Check the networking configuration and ensure that the aggregation ports are operating properly 3 31 134243773 EFM remote link event Notification Property l Notification Code 134243773 l Notification Information The notification is reported if EFM receiv...

Страница 116: ...onds of the MAC layer within the unit time exceeds the preset threshold Handling Procedure Contact the network engineer and optimize the link performance 3 32 134243774 EFM loopback indication Notification Property l Notification Code 134243774 l Notification Information The notification is reported if EFM performs loopback indication l Notification Type Qos Alarm Sub code Description l Sub code 1...

Страница 117: ...134317731 l Notification Information The notification is reported if the configuration file is reloaded l Notification Type Equipment Alarm Sub code Description l Sub code 2 Loading front end configuration files fails l Sub code 3 Synchronizing back end whole table configuration files fails Effect on the System This notification affects the service quality If the configuration file is manually loa...

Страница 118: ...affect the services Possible Causes 1 If software upgrading through IDU fails the alarm may be due to that version files are incomplete or incorrect 2 If software upgrading in FTP mode fails the alarm may be due to that the FTP server setting or FTP software setting is incorrect the version files are incomplete or incorrect Handling Procedure It is a notification that notifies users to upgrade the...

Страница 119: ...fails 2 The ODU fails 3 The switchover can be caused by lost or abnormal clock signal from the enclosure hard resetting of the board board power off or hardware fault of the board Handling Procedure Refer to the handling suggestions of the corresponding alarms 3 37 134317745 ACM change Notification Property l Notification Code 134317745 l Notification Information The notification is reported if th...

Страница 120: ...tion The notification is reported when the system time is modified due to SNTP based time calibration l Notification Type Equipment Alarm Sub code Description None Effect on the System The traffic carried by the board is not affected but the performance data may become incomplete Possible Causes The system time is modified Handling Procedure Ensure that the SNTP server time is accurate 3 39 134317...

Страница 121: ...rce change Notification Property l Notification Code 134317749 l Notification Information The notification is reported if the main clock reference changes The information of the main clock reference reported contains RackNo SheifNo slotNo and portID l Notification Type Equipment Alarm Sub code Description None Effect on the System none Possible Causes Main clock reference source change Handling Pr...

Страница 122: ...ZXMW NR8250 Alarm and Notification Handling Reference This page intentionally left blank 3 26 SJ 20111008094748 008 2012 05 30 R1 1 ZTE Proprietary and Confidential ...

Страница 123: ...tral Processing Unit DSP Digital Signal Processor FE Fast Ethernet FPGA Field Programmable Gate Array GPS Global Positioning System GbE Gigabit Ethernet IDU Indoor Unit LMT Local Maintenance Terminal NDF Native Direct Function NMS Network Management Server ODU Optical Channel Data Unit OMC Operation Maintenance Center RTC Real Time Clock I ...

Страница 124: ...ZXMW NR8250 Alarm and Notification Handling Reference SDH Synchronous Digital Hierarchy SNTP Simple Network Time Protocol STM Synchronous Transfer Mode II ...