Chapter 2 Alarm
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
Slot ID
Effect on the System
There is no effect on services.
Possible Causes
1.
A board not configured on the LMT is inserted in a slot.
2.
The PM software is faulty and detects board signal from a slot without board.
Handling Procedure
1.
Check whether the board is inserted into the slot.
l
If yes, go to step 2.
l
If no, replace the PM board.
2.
Verify that the board needs to be configured.
l
If yes, configure the board through LMT.
l
If no, pull out the board.
2.1.4 134217728 Clock reference source lost
Alarm Property
l
Alarm Code: 134217728
l
Alarm Information: The alarm is reported if the RCU cannot detect the clock signal of
configured clock reference source.
l
Alarm Level: Minor
l
Alarm Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: RCU 1PPS+TOD clock lost;
l
Sub-code 2: RCU BITS clock lost;
l
Sub-code 4: Slot3 clock lost;
l
Sub-code 5: Slot4 clock lost;
l
Sub-code 6: Slot5 clock lost;
l
Sub-code 7: Slot6 clock lost;
l
Sub-code 8: Slot7 clock lost;
l
Sub-code 9: Slot8 clock lost;
l
Sub-code 10: RCU NMS clock lost;
l
Sub-code 11: RCU GbE clock lost;
l
Sub-code 12: 1588 clock lost.
2-3
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential