1-3
IM 704510-01E
Names and Functions of Parts
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
1.2
Setting/Execution Key and Rotary Knob
INITIALIZE
FILE
MODE
FUNCTION
INPUT
MARKER UTILITY
SAMPLE
DISPLAY
SCALE
MODE Key (Section 5.1)
Shows a menu used to set the sampling mode.
FUNCTION Key (Sections 5.2 to 5.8)
Shows a menu used to select the measurement function and the measurement
conditions for each measurement function.
SAMPLE Key (Sections 6.1 to 6.5 and 6.8)
Shows a menu used to set the gate, block sampling, arming, inhibit, and reference
clock.
INPUT Key (Sections 6.6 and 6.7)
Shows a menu used to set the input coupling, input impedance, and trigger mode.
DISPLAY Key (Sections 7.1 to 7.4, 8.1 to 8.3, and 8.6)
Shows a menu used to set the display format, statistical computation items, window,
and inter-symbol interference analysis.
SCALE Key (Section 8.4)
Shows a menu used to set manual scaling.
MARKER(INITIALIZE) Key (Sections 8.5 and 13.1)
Shows a menu used to set markers that are used to retrieve measured results.
Pressing the SHIFT key followed by this key shows a menu used to initialize the
settings.
UTILITY(FILE) Key (Sections 3.7, chapter 10, sections 11.3 to 11.10, 12.2 to 12.5,
13.2, 13.6, 13.7, 14.3, and 14.4)
Shows a menu used to set communication parameters, setup data store/recall, self
test, calibration, and other items. Pressing the SHIFT key followed by this key shows
a menu related to the storing or recalling of the setup data, measured results, and
statistical computation result and other items.
LOCAL
COPY MENU
SHIFT
COPY
AUTO
SCALE
AUTO SCALE(LOCAL) Key (Section 8.4)
Executes auto scaling. Pressing the SHIFT key followed by this key clears the remote
mode using the communication interface.
COPY(COPY MENU) Key (Sections 11.12 and 11.13)
Outputs the screen image data to the built-in printer or a storage medium. Pressing
the SHIFT key followed by this key shows a setup menu related to the output of the
screen image data.
SHIFT Key
Pressing this key once causes the LED to the left of the SHIFT marking to illuminate.
Then, pressing the MARKER (INITIALIZE) key, UTILITY (FILE), AUTO SCALE
(LOCAL) key, or COPY (COPY MENU) key enables the function indicated in the
parentheses of each key.
SINGLE
START/STOP
SINGLE Key (Section 4.2)
Makes a single measurement.
START/STOP Key (Section 4.2)
Pressing the key once starts repetitive measurements. Pressing the key again stops
the measurement. The measurement indicator (LED above the START/STOP key)
illuminates while measurement is in progress.