9-15
IM 704510-01E
Statistical Calculation and Inter-Symbol Interference Analysis
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
Pulse Width A
→
A-to-B Time Interval Measurement
When the trigger is set to Single (Space)
Analyzes the A
↓
B
↑
data from the front edge of Space (3T)
3T
Space
Mark
Mark
3T 3T
3T
6T
11T
11T
14T
7T
Space Space
Space
Mark
Mark
Mark
Setting
Mode: ISI
Function: PWA
→
TI
> Slope: PW or PW A
↓
B
↑
Display > Window: Window setting suitable for the measured signal
> ISI Setting > Mode: Single
> Polarity:
> Trigger:
> : 3T
> Target: Prev A
↓
B
↑
(indicates the front edge of 3T Space)
:+
A B
CH A measurement
CH B measurement
Trigger
Trigger
Trigger
Analyzes the applicable A
↓
B
↑
data.
Histogram display of
all Mark data
Histogram display of
extracted Mark data
Set “analyze the A
↓
B
↑
data,
the front edge of
Space(3T)-Mark(7T)
sequence"
Statistical values of
the extracted Mark data
Statistical values of
all Mark data
Note
Due to the limitation of the continuous measurement conditions, signals can be acquired at
higher speeds when PWA
→
A
↑
B
↑
or PWA
→
A
↓
B
↑
is selected as compared to when
PWA
→
A B
is selected (see “Continuous Measurement Conditions” on page2-7).
9.3 Examples of Inter-symbol Interference Analysis