YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
77
1.3 C: Tuning
Pa
ra
m
et
er D
et
ai
ls
1
1.3
C: Tuning
C parameters are used to set the acceleration and deceleration characteristics, as well as S-
curves. Other parameters in this group cover settings for slip compensation, torque
compensation, and carrier frequency.
◆
C1: Acceleration and Deceleration Times
■
C1-01 to C1-08: Accel/Decel Times 1 to 4
Four different sets of acceleration and deceleration times can be set in the drive. They can be
selected by digital inputs, by the motor selection, or can be switched automatically.
Acceleration time parameters always set the time to accelerate from 0 to the maximum
output frequency (E1-04). Deceleration time parameters always set the time to decelerate
from maximum output frequency to 0. C1-01 and C1-02 are the default active accel/decel
settings.
Switching Acceleration Times by Digital Inputs
Accel/decel. times 1 are active by default if no input is set. The accel/decel times 2, 3 and 4
can be activated by digital inputs (H1-
Table 1.24 Accel/decel. Time Selection by Digital Input
No.
<1> The setting range for the acceleration and deceleration times is determined by C1-10 (Accel/Decel Time Setting
Units). For example, if the time is set in units of 0.01 s (C1-10 = 0), the setting range becomes 0.00 to 600.00 s.
Name
Setting Range
Default
C1-01
Acceleration Time 1
0.0 to 6000.0 s
10.0 s
C1-02
Deceleration Time 1
C1-03
Acceleration Time 2
C1-04
Deceleration Time 2
C1-05
Acceleration Time 3 (Motor 2 Accel Time 1)
C1-06
Deceleration Time 3 (Motor 2 Decel Time 1)
C1-07
Acceleration Time 4 (Motor 2 Accel Time 2)
C1-08
Deceleration Time 4 (Motor 2 Accel Time 2)
Accel/Decel Time Sel. 1
H1-
= 7
Accel/Decel Time Sel. 2
H1-
= 1A
Active Times
Acceleration
Deceleration
0
0
C1-01
C1-02
1
0
C1-03
C1-04
Содержание OYMC V1000
Страница 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Страница 294: ...2 12 Self Diagnostics 294 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...