1.5 E: Motor Parameters
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
125
Pa
ra
m
et
er D
et
ai
ls
1
Figure 1.43
Figure 1.43 PM Motor Code
■
E5-02: Motor Rated Power (PM OLV)
Sets the rated power of the motor.
Note:
This parameter is not reset when the drive is initialized using A1-03.
■
E5-03: Motor Rated Current (PM OLV)
Sets the motor rated current in amps.
Note:
1.
The resolution of E5-03 depends on the rated output power of the drive. If a drive is set up for 7.5 kW
rated output power (ND or HD rating) the value will have two decimal places. It will have one decimal
place if a drive is set up for 11 kW and higher.
2.
This parameter is not reset when the drive is initialized using A1-03.
■
E5-04: Number of Motor Poles (PM OLV)
Sets the number of motor poles.
Note:
This parameter is not reset when the drive is initialized using A1-03.
No.
Parameter Name
Setting Range
Default
E5-02
Motor Rated Power
0.10 to 18.50 kW
Depending on
E5-01
No.
Parameter Name
Setting Range
Default
E5-03
Motor Rated Current
10 to 200% of drive
rated current
Depending on
E5-01
No.
Parameter Name
Setting Range
Default
E5-04
Number of Motor Poles
2 to 48
Depending on
E5-01
0 0 0 0
0: 1800 r/min Series
1: 3600 r/min Series
2: 1750 r/min Series
3: 1450 r/min Series
4: 1150 r/min Series
F: Special Motor
Motor Voltage Class
and Capacity
0: Pico Motor
(SMRA Series)
1: Derated Torque for IPM
Motors
(SSR 1 Series)
Содержание OYMC V1000
Страница 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Страница 294: ...2 12 Self Diagnostics 294 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...