A.2 Parameter Table
312
YASKAWA ELECTRIC
SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
d1-11
Frequency Reference
11
Frequency reference when digital inputs "Multi-
Step Speed Reference 2, 4" (H1-
= 4 and 32)
are on.
0.00 to
400.00
Hz
0.00
Hz
A A A
28C
d1-12
Frequency Reference
12
Frequency reference when digital inputs "Multi-
Step Speed Reference 1, 2, 4" (H1-
= 3, 4,
32) are on.
0.00
Hz
A A A
28D
d1-13
Frequency Reference
13
Frequency reference when digital inputs "Multi-
Step Speed Reference 3, 4" (H1-
= 5 and 32)
are on.
0.00
Hz
A A A
28E
d1-14
Frequency Reference
14
Frequency reference when digital inputs "Multi-
Step Speed Reference 1, 3, 4" (H1-
= 3, 5,
32) are on.
0.00
Hz
A A A
28F
d1-15
Frequency Reference
15
Frequency reference when digital inputs "Multi-
Step Speed Reference 2, 3, 4" (H1-
= 4, 5,
32) are on.
0.00
Hz
A A A
290
d1-16
Frequency Reference
16
Frequency reference when digital inputs "Multi-
Step Speed Reference 1, 2, 3, 4" (H1-
= 3, 4,
5, 32) are on.
0.00
Hz
A A A
291
d1-17
Jog Frequency
Reference
Frequency reference when digital inputs "Jog
Frequency Reference", "Forward Jog" or
"Reverse Jog." are on. "Jog Frequency
Reference" has priority over "Multi-Step Speed
Reference 1 to 16”.
6.00
Hz
S S S
292
d2: Frequency Upper and Lower Limits
Use d2 parameters to configure the frequency reference limits.
d2-01
Frequency Reference
Upper Limit
Sets the frequency reference upper limit as a
percentage of maximum output frequency (E1-
04). Output speed is limited to this value even if
the frequency reference is higher. This limit
applies to all frequency reference sources.
0.0 to
110.0
100.0
%
A A A
289
d2-02
Frequency Reference
Lower Limit
Sets the frequency reference lower limit as a
percentage of maximum output frequency (E1-
04). Output speed is limited to this value even if
the frequency reference is lower. This limit
applies to all frequency reference sources.
0.0 to
110.0
0.0% A A A
28A
d2-03
Master Speed
Reference Lower
Limit
Sets the minimum frequency reference lower
limit if the frequency reference is input using an
analog input. Set as a percentage of maximum
output frequency (E1-04). The higher of both
values d2-01 and d2-03 will be the lower limit.
0.0 to
110.0
0.0% A A A
293
No.
Name
Description
Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
O
LV
P
M
Содержание OYMC V1000
Страница 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Страница 294: ...2 12 Self Diagnostics 294 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...