1.8 L: Protection Functions
214
YASKAWA ELECTRIC
SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
■
Mechanical Weakening Detection
This function can be used to detect mechanical weakening of a machine that leads to
overtorque or undertorque situations after a certain machine operation time has elapsed.
The function is activated in the drive when the cumulative operation counter U4-01 exceeds
the time set in parameter L6-11. Mechanical weakening detection uses the torque detection 1
settings (L6-01/02/03) and triggers an OL5 fault when overtorque or undertorque occurs in
the speed range determined by parameter L6-08/09. The OL5 operation is set by parameter
L6-08.
To output a signal for mechanical weakening detection, set H2-01, H2-02, or H2-03 to 22.
■
L6-08: Mechanical Weakening Detection Operation
Decides in which speed range the function is active and sets the mechanical weakening
detection operation.
Setting 0: Disabled
Setting 1: Continue Running if the Speed is Greater than L6-09 (signed) - Alarm
Detection when the speed is above L6-09 (signed). Upon detection the operation is
continued but an OL5 alarm is output.
Setting 2: Continue Running if the Speed is Greater than L6-09 - Alarm
Detection when the speed is above L6-09 (unsigned). Upon detection the operation is
continued but an OL5 alarm is output.
Setting 3: Stop when Motor Speed is Greater than L6-09 (signed)
Detection when the speed is above L6-09 (signed). Upon detection the operation is stopped
and an OL5 fault is output.
Setting 4: Stop when Motor Speed is Greater than L6-09
Detection when the speed is above L6-09 (unsigned). Upon detection the operation is
stopped and an OL5 fault is output.
No.
Name
Setting Range
Default
L6-03
Torque Detection Time 1
0.0 to 10.0 s
0.1 s
L6-06
Torque Detection Time 2
0.0 to 10.0 s
0.1 s
No.
Name
Setting Range
Default
L6-08
Mechanical Weakening Detection
0 to 8
0
Содержание OYMC V1000
Страница 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Страница 294: ...2 12 Self Diagnostics 294 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...