62
Appendix-4: Parameter Table [continued]
No.
Parameter Name
Initial
Value
Setting
Value
No.
Parameter Name
Initial
Value
Setting
Value
H3-01
Signal Level Selection (Terminal A1)
(Term A1 Signal)
0
H6-04
Pulse Train Input Bias
(Pulse Train Input Bias)
0.0
H3-02
Gain (Terminal A1)
(Terminal A1 Gain)
100.0
H6-05
Pulse Train Input Filter Time
(Pulse Output Sel)
0.10
H3-03
Bias (Terminal A1)
(Term A1 Bias)
0.0
H6-06
Pulse Train Monitor Selection
(Pulse Output Sel)
2
H3-08
Multi-Function Terminal A2 Signal
Level Selection
(Term A2 Signal)
2
H6-07
Pulse Train Monitor Scaling
(PO Sealing)
1440
H3-09
Multi-Function Analog Input Terminal
A2 Function Selection
(Terminal A2 Sel)
0
L1-01
Motor Protection Selection
(MOL Fault Select)
1
H3-10
Gain (Terminal A2)
(Terminal A2 Gain)
100.0
L1-02
Motor Protection Time Constant
(MOL Time Const)
1.0
H3-11
Bias (Terminal A2)
(Terminal A2 Bias)
0.0
L1-03
Alarm Operation Selection During Motor
Overheating
(MOL Thm Input)
3
H3-12
Analog Input Filter Time Constant
(Filter Avg Time)
0.03
L1-04
Motor Overheat Heating Operation
Selection
(MOL Filter Time)
1
H3-13
Terminal A1/A2 Switching
0
L1-05
Motor Temperature Input Filter Time
Constant
(MOL Filter Time)
0.20
H4-01
Monitor Selection (Terminal FM)
(Terminal FM Sel)
2
L3-01
Stall Prevention Selection During Accel
(StallP Accel Sel)
1
H4-02
Gain
(Terminal FM)
(Terminal FM Gain)
100
L3-02
Stall Prevention Level During Accel
(StallP Accel Lvl)
150
H4-03
Bias (Terminal FM)
(Terminal FM Bias)
0.0
L3-03
Stall Prevention Limit During Accel
(StallP AHP Lvl)
50
H4-04
Monitor Selection (Terminal AM)
(Terminal AM Sel)
3
L3-04
Stall Prevention Selection During Decel
(StallP Decel sel)
0
H4-05
Gain (Terminal AM)
(Terminal AM Gain)
50
L3-05
Stall Prevention Selection During Running
(StallP Run Level)
1
H4-06
Bias (Terminal AM)
(Terminal AM Bias)
0.0
L3-06
Stall Prevention Level During Running
(StallP Run Level)
160
H4-07
Analog Output 1 Signal Level Selection
(AO Level Select 1)
0
L4-01
Speed Agreement Detection Level
(Spd Agree Level)
0.0
H4-08
Analog Output 2 Signal Level Selection
(AO Level Select 2)
0
L4-02
Speed Agreement Detection Width
(Spd Agree Width)
2.0
H5-01
Station Address
(Serial Comm Adr)
1f
L4-03
Speed Agreement Detection Level (+/-)
(Spd Agree Lvl +-)
0.0
H5-02
Communication Speed Selection
(Serial Baud Rate)
3
L4-04
Speed Agreement Detection Width (+/-)
(Spd Agree Width +-)
2.0
H5-03
Communication Parity Selection
(Serial Com Sel)
0
L4-05
Operation When Frequency Reference is
Missing
(Ref Loss sel)
0
H5-04
Stopping Method After Communication
Error
(Serial Fault Sel)
3
L4-06
Frequency reference when freq. missing
80
H5-05
Communication Errer Detection
Selection
(Serial Flt Dtet)
1
L7-01
Forward
Drive
Torque Limit
(Torq Limit Fwd)
200
H5-06
Send Wait Time
(Transmit Wait TIM)
5
L7-02
Reverse
Drive
Torque Limit
(Torq Limit Rev)
200
H5-07
RTS Control ON/OFF
(RTS Control Sel)
1
L7-03
Forward Regenerative Torque Limit
(Torq Lmt Fwd Rgn)
200
H6-01
Train Input Function Selection
(Pulse Input Sel)
0
L7-04
Reverse Regenerative Torque Limit
(Torq Lmt Rev Rgn)
200
H6-02
Pulse Train Input Sealing
(Pl Sealing)
1440
L7-06
Integral Time Setting for Torque Limit
(Torq Limit Time)
200
H6-03
Pulse Train Input Gain
(Pulse Input Gain)
100.0
L7-07
Control Method Selection for Torque
Limit During Acceleration Deceleration
(Torque Limit Sel)
0
*Factory settings vary based on drive capacity.