17
L8-09
Ground
Protection
Selection
(Ground Fault
Sel)
0,1
1
1
0: Ground protection disabled.
1: Ground protection enabled.
N
A
A
A
A
4B5H
L8-10
Cooling Fan
Control
Selection
(FAN Control
Sel)
0,1
1
0
0: Fan On-Run Mode - Fan will
operate only when the Drive is
running and for L8-11 seconds
after RUN is removed.
1: Fan Always On - Cooling fan
operates whenever the Drive is
powered up.)
N
A
A
A
A
4B6H
L8-11
Cooling Fan
Control Delay
Time
(FAN OFF TIM)
0~300
1sec
60
N
A
A
A
A
4B7H
L8-12
Ambient
Temperature
(Temp)
45~60
1ºC
45
N
A
A
A
A
4B8H
L8-15
OL2 at low
frequency
selection
0,1
1
1
0 :OL2 detection at low frequency
disabled.
1 :OL2 detection at low frequency
enabled.
N
A
A
A
A
4BBH
L8-18
Soft CLA
Selection
(Soft CLA Sel)
0,1
1
0
0: Soft CLA Disabled (Gain = 0)
1: Soft CLA Enabled
N
A
A
A
A
4BEH
N1-01
Hunting-Prevent
ion Function
Selection
(Hunt Prev
Select)
0,1
1
1
0: Hunting Prevention Fun ction
disabled.
1: Hunting Prevention Function
enabled.
N
A
A
N
N
580H
N1-02
Hunting-Prevent
ion Gain
(Hunt Prev
Gain)
0.00~
2.50
0.01
1.00
N
A
A
N
N
581H
HuntingPrevention
N1-03
0~500
1msec
10
msec
N2-01
Speed Feedback
Detection
Control (AFR)
Gain
(AFR Gain)
0.00~
10.00
0.01
1.00
N
N
N
A
N
584H
N2-02
Speed Feedback
Detection
Control (AFR)
Time Constant
(AFR Time)
0~2000
1ms
50
N
N
N
A
N
585H
Speed Feedback Detection
N2-03
Speed Feedback
Detection
Control (AFR)
Time Constant 2
(AFR Time 2)
0~2000
1ms
750
N
N
N
A
N
586H
Table 4.2.2 Parameter Table (11)
Parameter Access Level
Note-2
Function
No.
Parameter Name
(Digital Operator
Display)
Setting
Range
Setting
Units
Factory
Settings
Comments
Chan
ges
on
the
Fly
V/f
V/f
w/P
G
OLV CLV
Memo
bus
Address
o1-01
Monitor Selection
(Monitor Select)
4~50
**
1
6
**Setting range will vary based on
Control Mode (refer to attached
table).
Y
A
A
A
A
500H
o1-02
Monitor Selection
After Power Up
(Power-On
Monitor)
1~4
1
1
1: Frequency Ref 3: Output
Current
2: Output Frequency
Y
A
A
A
A
501H
o1-03
Frequency Units
of Reference
Setting and
Monitor
(Display Scaling)
0~
39999
1
0
0: 0.01Hz Units 40~39999: Random
Setting
1: 0.01%
2~39: r/min
N
A
A
A
A
502H
o1-04
Setting Unit for
Frequency
Constants Related
to V/f
Characteristics
(V/f Display Unit)
0,1
1
0
0: Hz
1: r/min
N
N
N
N
A
503H
Display Settings / Selections
o1-05
LCD Brightness
Adjustment
(LCD Contrast)
0~5
*
1
3
*A setting of "1" is the lightest
contrast and a setting of "5" is the
darkest contrast.
Y
A
A
A
A
504H
Multi
-Function
Selection
o2-02
STOP Key During
Control Circuit
Terminal
Operation
(Oper STOP Key)
0,1
1
1
0: Enabled when the Run Command
is given from the operated.
1: Normally enabled.
N
A
A
A
A
506H