59
Appendix-4: Parameter Table
Initial values shown here are for the Open Loop Vector Control Mode, with a 200V 0.4kW drive.
No.
Parameter Name
Initial
Value
Setting
Value
No.
Parameter Name
Initial
Value
Setting
Value
A1-00
Language Selection
(Select Language)
0
*1
C1-06
Deceleration Time 3
(Decel Time 3)
10.0
A1-01
Access Level
(Access Level)
2
C1-07
Acceleration Time 4
(Accel Time 4)
10.0
A1-02
Control Method Selection
(Control Method)
2
*1
C1-08
Deceleration Time 4
(Decel Time 4)
10.0
A1-03
Initialize Parameters
(Init Parameters)
0000
C1-09
Emergency Stop Time
(Fast Stop Time)
10.0
A1-04
Password 1
(Enter Password)
0000
C1-10
Accel/Decel Time Setting Units
(Acc/Dec Units)
1
A1-05
Password 2
(Select Password)
0000
C1-11
Accel/Decel Switching Frequency
(ACC/Dec SW Freq)
0.0
A2-01~
A2-32
User Parameter 1 (thru 32)
(User Parameter 1 to 32)
-
C2-01
S-Curve Characteristic Time at
Acceleration Start
(SCrv Acc @ Start)
0.20
b1-01
Frequency Reference Selection
(Reference Source)
1
C2-02
S-Curve Characteristic Time at
Acceleration End
(SCrv Acc @ End)
0.20
b1-02
Operation Method Selection
(Rum Source)
1
C2-03
S-Curve Characteristic Time at
Deceleration Start
(SCrv Dec @ St art)
0.20
b1-03
Stop Method Selection
(Stopping Method)
0
C2-04
S-Curve Characteristic Time at
Deceleration End
(SCrv Dec @ End)
0.00
b1-04
Reverse Operation Selection
(Reverse Oper)
0
C3-01
Slip Compensation Gain
(Slip Comp Gain)
1.0
*2
b1-05
Operation Selection for Setting of E1-09
or Less
(Zero-Speed Oper)
0
C3-02
Slip Compensation Primary Delay Time
(Slip Comp Time)
200
*2
b1-06
Read Sequence Input Twice
(Cntl Input Seans)
1
C3-03
Slip Compensation Limit
(Slip Comp Limit)
200
b2-01
Zero Sp eed Level (DC Injection Braking
Staring Frequency)
(DC Inj Start Freq)
0.5
C3-04
Slip Compensation Selection During
Regeneration
(Slip Comp Regen)
0
b2-02
DC Injection Braking Current
(DC Inj Current)
50
C3-05
Output Voltage Limit Operation Selection
(Output V Limit)
0
b2-03
DC Injection Braking Time at Start
(DC Inj Time @ Start)
0.00
C4-01
Torque Compensation Gain
(Torq Comp Gain)
1.00
DC Injection Braking Time at Stop
(DC Inj Time @ Stop)
C4-02
Torque Compensation Primary Delay Time
Constant
(Torq Comp Time)
20
*2
b2-04
Stop Timer
(Stop Timer)
0.00
*2
C5-01
ASR Proportional
(P)
Gain 1
(ASR P Gain 1)
20.00
*2
b2-08
Magnetic Flux Compensation Volume
(Field Comp)
0
C5-02
ASR Integral
(I)
Time 1
(ASR I Time 1)
0.500
*2
b7-01
Droop Control
gain
(Droop Quantity)
0.0
C5-03
ASR Proportional
(P)
Gain 2
(ASR P Gain 2)
20.00
*2
b7-02
Droop Control Delay Time
(Droop Delay Time)
0.05
C5-04
ASR Integral
(I)
Time 2
(ASR I Time 2)
0.500
*2
b9-01
Zero Servo
gain
(Zero Servo Gain)
5
C5-05
ASR Limit
(ASR Limit)
5.0
b9-02
Zero Servo Completion Width
(Zero Servo Count)
10
C5-06
ASR Primary Delay Time
(ASR Delay Time)
0.004
C1-01
Acceleration Time
1
(Accel Time 1)
10.0
C5-07
ASR Switching Frequency
(ASR Gain SW Freq)
0.0
C1-02
Deceleration Time
1
Decel T ime 1)
10.0
C5-08
ASR Integral Limit
(ASR I Limit)
400
C1-03
Acceleration Time
2
(Accel Time 2)
10.0
C1-04
Deceleration Time
2
(Decel Time 2)
10.0
C1-05
Acceleration Time 3
(Accel Time 3)
10.0
*1 Not reset when the drive is initialized (standard specs within Japan are A1-00 = 1, A1-02 = 2)
*2 Factory/default settings will vary based on the Control Mode (A1-02).