32
4.2.5 (3) Parameters that change based on drive capacity (o2-04):
(400V Class)
No.
Name
Units
Factory Settings
--
Inverter Capacity
kW
E2-11
Motor rated Output
1
E4-07
Motor 2 Rated Output
1
220
300
o2-04
Drive/kVA Selection
kHz
36
37
C6-02
Carrier Frequency Selection
--
1
*1
1
*1
--
Upper Limit of Carrier Frequency
--
1
1
E2-01
(E4-01)
Motor Rated Current
A
370.0
500.0
E2-02
(E4-02)
Motor Rated Sl ip
Hz
1.30
1.25
E2-03
(E4-03)
Motor No-Load Current
A
96.0
130.0
E2-05
(E4-05)
Number of Motor Poles
?
0.020
0.014
E2-06
(E4-06)
Motor Line-to-Line Resistance
%
20.0
20.0
E2-10
Motor Iron Loss for Torque
Compensation
W
3700
4700
L8-02
Overheat Alarm Level
ºC
110
115
E1-11
Motor Output Power
kW
220.00
300.00
*1
Displays 0: Low Noise PWM, 1: 2kHz, 2: 5.0kHz, 3: 8.0kHz, 4: 10kHz, 5: 12.5kHz,
6:15kHz,
F: Random Setting (initial value is 3kHz for 400V 90kW/110kW).
5. Test Run
Be sure to also check the following:
¦ Check the Output Current when operating the drive at the maximum load:
・
Verify that the output current does not exceed 1 50% of the drive rated current when the brake is applied and released
during both start and stop.
・
Be sure that the output current doesn't exceed the motor rated current when running continuously.
The following counter-measures can be taken when the output current exceeds the levels mentioned above:
・
Perform Auto-tuning (unless Auto-Tuning has already been performed).
・
With motor only (no mechanical connection).
・
Refer to Appendix-1, "Parameter Calculations", as well as Appendix-3, "Tuning Procedures", and then tune/set
drive parameters as indicated.
・
If there is excessive current when starting to hoist just after lowering the load while operating in V/f or Open Loop
Vector Control Modes, then adjust the setting in parameter S2 -03 ( Run Command Delay Timer (REV? FWD)). See
section 6.2.2, “Operation Command Delay Timer (Reverse? Forward)” for a detailed description of how the timer
works.
¦ If other errors occur while peforming a test run, then see the check list in Appendix-2 for appropriate counter-measures.