60
Appendix-4: Parameter Table [continued]
No.
Parameter Name
Initial
Value
Setting
Value
No.
Parameter Name
Initial
Value
Setting
Value
C6-02
Carrier Frequency Selection
(Carrier Freq Sel)
1
d4-02
±
Speed Limits
(Trim Control Lvl)
10
C6-03
Carrier Frequency Upper Limit
(Carrier Freq Max)
*2
E1-01
Input Voltage Setting
(Input Voltage)
200
*3
C6-04
Carrier Frequency Lower Limit
(Carrier Freq Min)
*2
E1-03
V/f Pattern Selection
(V/f Selection)
F
C6-05
Carrier Frequency Proportional Gain
(Carrier Freq Gain)
00
E1-04
Max Output Frequency
(Max frequency)
60.0
*1
d1-01
Frequency Reference 1
(Reference 1)
0.00
E1-05
Max Voltage
(Max Voltage)
200.0
*1 *3
d1-02
Frequency Reference 2
(Reference 2)
0.00
E1-06
Base Frequency
(Base frequency)
60.0
*1
d1-03
Frequency Reference 3
(Reference 3)
0.00
E1-07
Mid Output Frequency
(Mid Frequency A)
3.0
*1
d1-04
Frequency Reference 4
(Reference 4)
0.00
E1-08
Mid Output Voltage
(Mid Voltage A)
12.0
*1 *3
d1-05
Frequency Reference 5
(Reference 5)
0.00
E1-09
Min Output Frequency
(Min Frequency)
0.5
*1
d1-06
Frequency Reference 6
(Reference 6)
0.00
E1-10
Min Output Frequency Voltage
(Min Voltage)
2.0
*1 *3
d1-07
Frequency Reference 7
(Reference 7)
0.00
E1-11
Mid Output Frequency 2
(Mid Frequency 2)
0.0
*4
d1-08
Frequency Reference 8
(Reference 8)
0.00
E1-12
Mid Output Frequency Voltage 2
(Mid Voltage 2)
0.0
*4
d1-09
Frequency Reference 9
(Reference 9)
0.00
E1-13
Base Voltage
(Base Voltage)
0.0
*5
d1-10
Frequency Reference 10
(Reference 10)
0.00
E2-01
Motor Rated Current
(Motor Rated FLA)
1.90
*2
d1-11
Frequency Reference 11
(Reference 11)
0.00
E2-02
Motor Rated Slip
(Motor Rated Slip)
2.90
*2
d1-12
Frequency Reference 12
(Reference 12)
0.00
E2-03
Motor No-Load Current
(No-Load Current)
1.20
*2
d1-13
Frequency Reference 13
(Reference 13)
0.00
E2-04
Number of Motor Poles
(Number of Poles)
4
d1-14
Frequency Reference 14
(Reference 14)
0.00
E2-05
Motor Line-to-Line Resistance
(Term Resistance)
9.842
*2
d1-15
Frequency Reference 15
(Reference 15)
0.00
E2-06
Motor Leak Inductance
(Leak Inductance)
18.2
*2
d1-16
Frequency Reference 16
(Reference 16)
0.00
E2-07
Motor Iron-Core Saturation Coefficient 1
(Saturation Comp 1)
0.50
d1-17
Jog Frequency Reference
(Jog Reference)
6.00
E2-08
Motor Iron-Core Saturation Coefficient 2
(Saturation Comp 2)
0.75
d2-01
Frequency Reference Upper Limit
(Ref Upper Limit )
100.0
E2-09
Motor Mechanical Loss
(Mechanical Loss)
0.0
d2-02
Frequency Reference Lower Limit
(Ref Lower Limit)
0.0
E2-10
Motor Iron Loss for Torque Compensation
(Tcomp Iron Loss)
14
*2
d2-03
Master Speed Reference Lower Limit
(Ref1 Lower Limit)
0.0
E2-11
Motor Rated Output
(Mtr Rated Power)
0.40
*2
d3-01
Jump Frequency 1
(Jump Freq 1)
0.0
E2-12
Motor Iron Saturation Coeffecient 3
(Saturation Comp 3)
1.30
d3-02
Jump Frequency 2
(Jump Freq 2)
0.0
E3-01
Motor 2 Control Method Selection
(Control Method)
2
REV-
7
d3-03
Jump Frequency 3
(Jump Freq 3)
0.0
E3-02
Motor 2 Max. Output Frequency (FMAX)
(Max Frequency)
60.0
*1
d3-04
Jump Frequency Width
(Jump Bandwidth)
1.0
E3-03
Motor 2 Max. Voltage (VMAX)
(Max Voltage)
200.0
*1 *3
d4-01
Frequency Reference Hold Function
Selection
(MOP Ref Memory)
0
E3-04
Motor 2 Max. Voltage Frequency (FA)
(Base Frequency)
60.0
*1
*1 Factory/default settings will vary based on Control Mode (A1-02), or by the value set to parameter E3-01.
*2 Both the setting range and factory/default settings will vary based on drive capacity.
*3 Values shown here are for 200V class drives. Double values when working with 400V class drives.
*4 Setting disregarded when E1-11 or E1-12 are set to zero.
*5 Parameter E1-13 will equal the setting of E1-05 when Auto-Tuning is performed.
Содержание CIMR-F7Z