Chapter 3
Main Panel Window
DME Designer Owner’s Manual
104
• [Mute]
GPI input can be used to engage or disengage the DME mute function.
[Parameter], [Min], and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
Mute will be ON when the voltage applied to GPI IN is above the median voltage*, and OFF when the
voltage is below the median.
Mute will be OFF when the voltage applied to GPI IN is above the median voltage*, and ON when the
voltage is below the median.
Mute will be alternately turned ON and OFF each time the voltage applied to GPI IN drops from
below to above the median voltage.*
Mute will be alternately turned ON and OFF each time the voltage applied to GPI IN rises from above
to below the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
Mute ON
Mute OFF
Mute OFF
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
Mute OFF
Mute ON
Mute ON
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
ON
ON
OFF
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
ON
ON
OFF