Chapter 3
Main Panel Window
DME Designer Owner’s Manual
106
• [Time Adjustment]
GPI input can be used to adjust the DME internal clock as follows:
[Parameter], [Min], and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
and
specify continuous control of continuously-variable parameters from an external
fader, knob, or similar device.
and
specify on/off control of 2-state parameters via an external switching device.
The internal clock time will be adjusted each time the voltage applied to GPI IN rises from below to
above the median voltage.*
The internal clock time will be adjusted each time the voltage applied to GPI IN drops from above to
below the median voltage.*
Same as
.
Same as
.
Internal clock time
Time after adjustment
0~14 seconds
Returned to 0 seconds
15~29 seconds
Advanced to 30 seconds
30~44 seconds
Returned to 30 seconds
45~59 seconds
Advanced to 0 seconds
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
Trigger
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
Trigger